Error Conditions:
Each of the LEDs stepping smoothly from one to the next
Indicates that there is no SD card present.
With units prior to serial No. 13000, SD card errors are also reported by each of
the LEDs stepping smoothly from one to the next.
All three LEDs flashing together
Indicates that there is a problem with the SD card
Single LED permanently on
Indicates download failure
Single LED on briefly (approx 3s)
Indicates button press while Digidown is busy
Suggested Actions on Error Condition
SD Card Error:
Check card is correctly inserted
Check card Lock Switch is in the unlocked position
Check card is not full
Check card is formatted as FAT16
(Windows refers to this format as FAT)
Download Failure:
Ensure that a Company, Control or Workshop card is
inserted in the VU and that vehicle ignition is switched
on.
Retry download
Button Press Error:
No action required - original download will continue.
‘Download Fault 12’
When downloading data from some SiemensVDO
digital tachographs the message ‘Download Fault 12’ may occasionally be shown
on the tachograph display. This can safely be ignored. Allow the download to
finish and then press ‘OK’ to cancel the error message.
Choice of SD Memory Card
The Digidown will work successfully with most types of SD memory card provided
that they are formatted FAT16 (which Windows calls ‘FAT’). A few SD card types
are unfortunately not suitable as they do not conform fully to the SD card
specification. Cards supplied by Lisle Design are to be preferred as they have
been selected for optimum performance in this application.
2Gbyte memory cards are supplied as standard by Lisle Design (although lower
memory capacities are entirely adequate for this application). Larger capacity
memory cards are not suitable for use with the Digidown Plus.