background image

HCS GDC D1

TECHNICAL DESCRIPTION

APRIL 2019

4. Restart Mode

6

Restart is used when the drying process has been 

stopped and should be restarted. The control will 
then switch to Manual mode with the setting from last 
manual run.
 

The drying now runs for 60 minutes on Manual, 

and then on Auto with the setting used for the last pre-
vious auto run. The process continues as a standard 
auto run.

When Restart is used the Percentage setting cannot 
be changed. If requested, “Cancel” can be pressed to 
return to the start page in which Manual mode can be 
chosen to make the adjustment. 
 

Once Restart is pressed again, a new 60 minute 

manual run is restarted and switched over to Auto 
mode, and so on.

Press “Restart”

Step 1

Please write down the settings to facilitate for the next occasion 
the same kind of cereals are dried.

PV

: Shows the signal from the sensor.

Man

: Shows the percentage set.

Feed Out

: Lights up yellow when output is 

active.

Restart time

: Shows the number of minutes 

left before the control switches to Auto. 

Cancel: 

Press to exit Restart and go to the 

Home screen.

Step 2

Содержание GrainWatch HCS GDC D1

Страница 1: ...Grain Dryer Control HCS GDC D1 TECHNICAL DESCRIPTION...

Страница 2: ...DESCRIPTION APRIL 2019 Table of Contents 1 This is HCS GDC D1 2 Manual Mode 3 Auto Mode 4 Restart 5 Connecting the HCS GDC D1 6 Instrumentation Amplifier HCS 200 7 Mounting the Humidity Sensors HCS 4...

Страница 3: ...from humidity sensors and your own settings It has two modes Manual and Auto When in Manual mode the Humidity Sensors are not engaged When in Auto mode the signal from the Humidity Sen sors are used...

Страница 4: ...ess Auto Set after which the system will automati cally set a value corresponding to the one used in Manual mode If the Auto button is pressed directly without pre setting the control automatically sw...

Страница 5: ...at least one hour Then check that the adjustments support the desired result Normally the Auto value should be between 5 00 8 00 Lowest value for dry commodity oil seeds or commodity with a lot of sh...

Страница 6: ...cannot be changed If requested Cancel can be pressed to return to the start page in which Manual mode can be chosen to make the adjustment Once Restart is pressed again a new 60 minute manual run is r...

Страница 7: ...ntrol unit amplifier and any relays To control unit Outputs TR Out Amplifier Power Terminal 24V for Plus 0 V for Minus Q0 Feed Out active during feed out Q1 Alarm active during alarm Q2 Dry active whe...

Страница 8: ...B Connection with two sensors Amplifier Amplifier White White Green Green Brown Brown HCS GDC D1 TECHNICAL DESCRIPTION APRIL 2019 8...

Страница 9: ...ires The amplifier should be mounted close to the dryer in doors or outdoors between the Humidity Sensors and the HCS Place the amplifier where it is accessible for service There is approximately 1 me...

Страница 10: ...the dryer one or two HCS 4 3 can be installed Shown in the picture below right is the first row of beams members at the mark X where the drying zone meet up with the cooling zone Level wise HCS 4 3 s...

Страница 11: ...ut tools Tighten screw 2 and unscrew the two screws called 3 slightly Insert the HCS 4 3 inside the air beam air member The Sensor should rest in the triangular opening and the lip underneath must be...

Страница 12: ...www grainwatch com APRIL 2019...

Отзывы: