background image

SOLD AND SERVICED BY
A NETWORK OF HIGHLY TRAINED

FULL SERVICE DISTRIBUTORS

L I Q U I D

CONTROLS

    C O N T R O L S ,   L L C

105 Albrecht Drive
Lake Bluff, IL 60044-2242
Telephone: (847) 295-1050
FAX: (847) 295-1057
Website: www.lcmeter.com

Distributed By:

Backed By Our Worldwide Reputation For

Quality, Accuracy and Advanced Design.

 1999 Liquid Controls

Printed in U.S.A. (0799)

Bulletin #49137C

Warranty:
Liquid Controls, L.L.C. (“Seller”) products are warranted against
defects in materials or workmanship for a period of one (1) year
from date of installation, provided that the warranty shall not
extend beyond twenty-four (24) months from the date of original
shipment from seller. Seller’s obligations, set forth below, shall
apply only to failure(s) to meet the foregoing obligations
provided that seller is given written notice within (30) days of
any occurrence from which a claim of defect arises. If a warranty
dispute occurs, the purchaser shall be required to provide Seller
with proof of date of sale. The minimum requirement to establish
date of sale shall be a copy of the Seller’s invoice. In the event
that a factory inspection by Seller or its designee(s) supports the
validity of a claim, at the discretion of Seller, repair, replacement
or refund shall be sole remedy for defect

and shall be made, free of charge, ex-works factory. In no event
shall Seller be liable for any special, consequential, incidental,
indirect or exemplary damages arising out of warranty, contract,
tort, (including negligence) or otherwise, including but not
limited to, loss of profit or revenue, loss of use of the product or
any associated products and/or equipment, cost of substitute
goods or services, downtime costs or claims of or by Purchaser’s
clients or customers. In any event, the total liability  of Seller for
any and all claims arising out of  or resulting from the
performance, non-performance or use of the product shall not
exceed the purchase price of the individual product giving rise to
the claim. All other guaranties, warranties, conditions and
representations, either express or implied, whether arising under
any statute, common law, commercial usage or otherwise are
excluded. Electronic Products require

Installation, start-up and servicing by local factory-trained
service representatives. In the absence of installation, start-up and
servicing of Electronic Products by Seller trained service
representatives, this warranty is null and void. Seller’s
obligations as set forth above shall not apply to any product, or,
or any component part thereof, which is not properly installed,
used, maintained or repaired, or which is modified other than
pursuant to Seller’s instructions or approval. NOTE: The above
warranty applies only to products manufactured by Liquid
Controls, Lake Bluff, Illinois. Private label, OEM, and/or
products manufactured by Liquid Controls licensee(s) are
specifically excluded from the above warranty. Consult the
factory for all non-Liquid Controls manufacturers’ warranties.
NO IMPLIED OR STATUATORY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE SHALL APPLY.

Содержание LectroCount3

Страница 1: ...STANDARD BULK TRUCK SYSTEM STANDARD BULK TRUCK SYSTEM INSTALLATION PROCEDURES INSTALLATION PROCEDURES LectroCount...

Страница 2: ...ainer Cover Mounted Thermowells 16 17 10 2 Installation of Pipe Mounted Thermowells 18 10 2 1 For Canadian Installations 18 11 Mounting the Remote Supervisory Control Box RSCB 19 11 1 Liquid Controls...

Страница 3: ...you understand the total scope of the project Specific installation requirements will vary with the model of truck Meter type configuration of existing metering equipment selected options and the typ...

Страница 4: ...oid kit q Mount RSCB REC q Install pulser assembly optional q Install Electronic Temperature Volume Compensation Kit optional q Route Meter Signal Cable to truck cab 3 Parts Requirements 3 1 LIQUID CO...

Страница 5: ...Inspect all truck electrical electronic equipment for proper installation q Determine if the truck is positive or negative ground If the system is positive ground contact the factory q Be sure that th...

Страница 6: ...floor ground the SCM to the truck electrical system and route the power and signal cables to the appropriate connectors on the SCM and Dual Meter Switch The printer also needs to be mounted in the tr...

Страница 7: ...heavy duty ring terminals that must be installed directly to the battery posts Make sure that the truck s electrical system has been properly checked Clean the battery terminals for a good electrical...

Страница 8: ...ne end They are not terminated on the other end The accessory cable must be wired to the truck s accessory circuit The power to this circuit should be q OFF when the ignition is off or the engine is c...

Страница 9: ...e terminal block screw using 1 8 flat blade screwdriver q Plug the terminal black back into the SCM 5 4 TRUCK SEAT GROUNDING 5 4 1 Static Electricity and Grounding Static electricity can build up on d...

Страница 10: ...o the wood There must be good contact between the seat fabric and ground strap lug q Make sure that the strap is positioned so that it doesn t interfere with the movement of the seat or is exposed to...

Страница 11: ...11 A Air Cushion Type Seat Adjustable for Height Bostrom 914 Series Seat or Equivalent B Air Cushion Type Seat Adjustable for Height This includes Dura Form Seats or equivalent...

Страница 12: ...leading to electrostatic discharge problems The ground path should be checked whenever the LectroCount is serviced This ensures that the SCM s case remains properly grounded Checking for a good groun...

Страница 13: ...the cab The bolt used to ground the seat ground strap on the seat base is usually a good location Measure the resistance between the silver hex head screw and Pin3 again to make sure that the system...

Страница 14: ...that is Level Not subject to physical abuse Easy for the driver to reach Within reach of the printer s data and power cables Industrial strength Velcro supplied with the printer is used to hold the p...

Страница 15: ...ove the existing mechanical register components if present by removing the four bolts that attach the register stack to the meter and lifting the stack off of the meter If you are retrofitting to Nept...

Страница 16: ...strainer q Bolt the strainer cover in place ensuring that the weights and measures thermowell tip points downwards in the strainer q On some cover castings the designation this side up or an arrow is...

Страница 17: ...and a slotted metal disc Slide the foam washers down the RTD wires and position them at the tail end of the RTD q Re coat the RTD probe and insert it into the thermowell for the final time Position it...

Страница 18: ...e heat transfers from the liquid to the probe inside the thermowell q The Thermowell Installation kit also includes four foam washers and a slotted metal disc q Slide the foam washers down the RTD wir...

Страница 19: ...s w Temp Compensator 11 1 LIQUID CONTROLS METERS RSCB WITH INTERNAL PULSERS The internal pulser version of the RSCB allows traditional mechanical registration equipment to be easily replaced with the...

Страница 20: ...ith a static seal The motion of the meter rotor is magnetically coupled to the meter when a POD or other external pulser is used The RSCB is not mechanically coupled to the meter when a POD or other e...

Страница 21: ...bottom of the bracket Screw them into the Neptune meter Make sure that the bracket is flush with the meter casting q Tighten the cone tipped clamping screws until the conical tips engage firmly again...

Страница 22: ...e the washer Place the driver item 5 onto the drive shaft and secure with a cotter pin item 1 Avoid forcing the shaft into the RSCB housing q Position the weather plate item 8 on the bottom of the RSC...

Страница 23: ...e that the cover gasket is in place and that all 12 7 16 mounting bolts and washers are installed q Remove all of the pipe plugs from the RSCB s seven NPT conduit hubs Apply pipe sealant or Teflon tap...

Страница 24: ...conduit cable entrances must be sealed inside and out using appropriate cable glands to prevent moisture from accumulating in the RSCB Avoid chaffing or nicking the cables when pulling them through co...

Страница 25: ...en When wiring the solenoids into the RSCB junction box the wires may have to be spliced in order to reach the appropriate terminal strip location Use stranded 18 GA wire It is recommended that red wi...

Страница 26: ...OBE TO THE RSCB Make sure that there is enough slack in the conduit leading from the RSCB to the strainer mounted RTD to allow the strainer cover to be removed Feed the cable from the back of the RTD...

Страница 27: ...able down the inside edge of the truck s frame rail q Secure the cable to the frame rail every 18 to 24 inches with wire ties q Install rubber grommets to protect the cable where it passes through the...

Страница 28: ...Not Force the Connector In The connectors are keyed to ensure that the pins are properly aligned q After the connector has been properly inserted turn the securing ring clockwise at least turn q Each...

Страница 29: ...imeter Voltage levels are critical to proper system operation Use an accurate reliable multimeter to test for proper voltages at the start of any service procedures Voltage requirements are listed und...

Страница 30: ...und The DC voltage should be 12VDC or higher If the voltage is present ignition key in accessory replace the power supply board part 81213 If voltage is not present trace the accessory line back to it...

Страница 31: ...embly If after replacing the above units the fuse continues to blow it is possible that the pulser assembly is defective Replace the pulser board part 811521 for internal pulser part 81159 for POD typ...

Страница 32: ...r shorted circuit between RTD probe and Supervisory Control Module SOLUTION Check the RTD probe Signal harness for continuity Remove the signal harness gray black cable from the Supervisory Control Mo...

Страница 33: ...id Controls Service Department 1 800 458 5262 PROBLEM REC Counter does not reset register counts intermittently PROBABLE CAUSE Counter is not receiving pulses during delivery SOLUTION 1 Set up a deliv...

Страница 34: ...PROBLEM Pulser Failure appears on Lap Pad PROBABLE CAUSE Missing pulse counts excessive reversals SOLUTION 1 Determine which meter is causing the problem Attempt to make a delivery for products assig...

Страница 35: ...BLEM Valve will not open single stage PROBABLE CAUSE Solenoids Inactive Inoperative SOLUTION 1 In Mode 1 select a product code insert a delivery ticket into the EPSON printer and start a delivery 1 Mo...

Страница 36: ...he REC cover Lift the cover and remove the coiled phone cable Set the cover to the side taking care not to damage the phone type cable connector 2 Using a reliable voltmeter measure the following DC v...

Страница 37: ...Card Due to the complexity of the LectroCount 3 system this trouble shooting guide cannot cover all possible situations Call your local Liquid Controls Service Center or the Liquid Controls Electronic...

Страница 38: ...38 P N 70946 P N 70945 SINGLE METER TRUCK SYSTEM WIRING DIAGRAM NEGATIVE GROUND...

Страница 39: ...39 METER 1 REMOTE S C CONTROL BOX WIRING...

Страница 40: ...40 81242 SIGNAL CABLE DUAL METER TRUCK SYSTEM WIRING DIAGRAM NEGATIVE GROUND...

Страница 41: ...41 81340 81340 89044 NEGATIVE GROUND DUAL METER TRUCK SYSTEM LECTROCOUNT SHEET 1 OF 2 EO 320 REV A 1 2 96 E2535 1 DUAL METER SWITCH ASSEMBLY...

Страница 42: ...42 METER 1 REMOTE S C CONTROL BOX WIRING...

Страница 43: ...43 MOUNTING ARRANGEMENT FOR SYSTEMS WITH MOUNTING BRACKETS SINGLE METER SYSTEM DUAL METER SYSTEM...

Страница 44: ...f warranty contract tort including negligence or otherwise including but not limited to loss of profit or revenue loss of use of the product or any associated products and or equipment cost of substit...

Отзывы: