manualshive.com logo in svg
background image

USER FUNCTION 5 (U5)

The pre-amplifier has memories associated with each input which are used to store the volume,

balance and mono/stereo settings. The memories are also required for the “source level equalisation” function. The
memories are enabled when the option is 0.

Option 0 allows the pre-amplifier to remember automatically the last setting for volume, balance and mono/stereo. Option
1 disables the memories so that the setting of volume, balance and mono/stereo is the same for all listen inputs and the
“source level equalisation” function is disabled.

USER FUNCTION 6 (U6)

Two phone inputs, Ph1 and Ph2, are provided, but they cannot be used simultaneously, as men-

tioned earlier. Since most users are likely to have only one turntable, Option 1 or 2 restricts the input selection to the Ph1
or Ph2 input respectively.

USER FUNCTION 7 (U7)

Option 0 connects the signal from the front panel remote control sensor to the REMOTE OUT

socket. This allows the Kairn to act as a remote control receiver for other Linn equipment which may be in a concealed
location. In some installations this facility may not be required. If option 1 is selected, the REMOTE OUT socket is driven
only by signals connected to the REMOTE IN socket.

USER FUNCTION 8 (U8)

The listen source and volume after the Kairn is switched on are the same as those used last time

if the option is 0. When option 1 is selected, the listen source is unchanged but the volume is preset to 50 at switch-on.
When option 2 is selected, the listen source and volume setting at that instant are memorised. These settings are then
used each time the Kairn is switched on. This option could be used, for example, to select the ‘tun’ source at volume level
60 at switch-on irrespective of the settings used last time.

USER FUNCTION 9 (U9) 

When option 1 is selected, pressing any of the ‘tuner’ controls on the remote handset will auto-

matically set the Kairn listen source to ‘tun’. Similarly, pressing the ‘compact disc’ controls (except OPEN and STOP) on
the handset will set the listen source to ‘CD’. This facility is disabled when the option is set to 0.

USER FUNCTION 10 (U10)

Option 0 disables the control of the Kairn by a Linn multi-room system. Select option 1 to allow

the Kairn to be used in the main room of a Linn multi-room system which has Majik amplifiers but on Knekt Room Control
Units (RCU) in the remote rooms. The tape record path of the Kairn supplies audio via a Linn Knekt Driver. In each remote
room the desired source of the main system is selected by choosing the corresponding record input of the Kairn. This is
achieved by pressing the WHAT button on the Kairn remote handset or the MATRIX button on the handset of the Majik
amplifier. Note that the record source cannot be changed if the “record lock” is turned on.

USER FUNCTION 11 (U11)

Option 0 allows the AUX/AUX1 input to be used as a general purpose line-level input. Option 1

allows the Kairn to be used in conjunction with a surround sound processor to provide the front left and right audio chan-
nels. The surround sound processor should be connected to the AUX/AUX1 input of the Kairn. This input is specially con-
figured to have unity gain, corresponding to a volume setting of 80. The volume and channel balance is then controlled
by the surround sound processor. When selected this input is displayed as SSP and the volume, balance, and volume
functions are disabled. If any attempt is made to change the volume, and volume settings the display will change to show
SSP. The other Kairn inputs are unaffected.

NOTE: When option 1 is selected, User Function U8 should be set to U8 = 0. Otherwise, should the Kairn be ‘powered
down’ with SSP input selected, the volume will default to 50 instead of 80 as required by the SSP input.

USER FUNCTION 12 (U12)

Option 0 makes the record source selection independent from the listen source. This option

should be set when the Kairn is used in a multi-room system. Option 1 simplifies the selection of the record source by
making it follow the listen source. Thus whenever a listen source is selected the record input is set to be the same -
unless the ‘record lock’ is on.

To exit the “user function” mode, press any of the buttons 

RECORD     LISTEN     BALANCE

or   

VOLUME  

on the front panel, or

REC     LISTEN

on the handset. Alternatively, wait for the mode to time-out approximately twenty seconds after the last but-

ton press.

To restore all the User Functions to the original factory setting, first switch off the tuner, press and hold the - button and
switch on the power. When the display shows INIT, the button may be released. All User Options are then set on 0.

12

KAIRN ENG PLACED  11/27/02  9:27 AM  Page 17

Содержание KAIRN

Страница 1: ...K A I R N O W N E R S M A N U A L KAIRN ENG PLACED 11 27 02 9 26 AM Page 1 ...

Страница 2: ...KAIRN ENG PLACED 11 27 02 9 26 AM Page 2 ...

Страница 3: ... TO RAIN OR MOISTURE 7 6 i This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ...

Страница 4: ... the manufacturer 6a An appliance and cart combination should be used with care Quick stops excessive force and uneven surfaces may cause the appliance and cart combination to overturn 7 Wall or ceiling mounting Mount to a wall or ceiling only as recommended by the manufacturer 8 Ventilation Site the appliance so that its location or position does not interfere with its proper ventilation For exam...

Страница 5: ...to provide some protection against voltage surges and static build up In the USA see article 810 of the National Electrical Code ANSI NFPA 70 concerning installation requirements 17 Lightning storms Unplug this apparatus during lightning storms or when unused for long periods of time 18 Objects and liquid entry Do not let objects or liquids fall into the product Do not expose the product to drippi...

Страница 6: ... plug need replacing and you are competent to do this proceed as follows If you are in doubt contact your Linn retailer or a competent electrician a Disconnect the plug from the mains supply b Cut off the plug and dispose of it safely A plug with bared conductors is dangerous if engaged in a live socket c Only fit a 13 Amp BS1363A approved plug with a 5 Amp fuse d The cable wire colours or a lette...

Страница 7: ...appreciate music you never thought you would At Linn we devote our energy to improving standards of music reproduction because we know that the better the sound the more you ll enjoy music at home The addition of any Linn component will improve the sound quality of your system Linn has a policy of continuously improving its equipment allowing customers to retro fit most product upgrades 1 KAIRN EN...

Страница 8: ...Channel balance is maintained within 1 2 dB across the full range of the volume control and the tape output is fully buffered to prevent loading of the signal path The KAIRN accommodates seven input sources and provides three outputs for multi amplifier systems The KAIRN PRO has no phono input but has an additional line input AUX2 When using the remote control this AUX2 input is selected by pressi...

Страница 9: ...connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red All the input sockets on the Lin...

Страница 10: ...eo line outputs to enable the connection of up to three power amplifiers in your hi fi system thereby avoiding the need for adapter cables Select a line output and using the interconnect leads provided connect the left output on the pre amplifier to the left input on the power amplifier and the right output on the pre amplifier to the right input on the power amplifier NOTE When connecting to a Li...

Страница 11: ... output Always use a line output from the KAIRN direct to the power amplifier for the primary system in your home Additional systems may be connected through the matrix output REMOTE IN OUT The remote in and out facility on the KAIRN is also intended for use in a distributed system and is designed to enable remote control operation of various Linn products throughout your home ADDITIONAL CONNECTIO...

Страница 12: ...wo dashes To switch off the pre amplifier press and release the POWER button To show the current volume level press the VOLUME button The display shows the legend VOLUME and the level as a number in the range 0 100 The volume level can also be shown in decibels dB see User functions To increase or decrease the volume press the or buttons A single push on the buttons alters the volume by one step H...

Страница 13: ...to the seven possible inputs there is an eighth state in which no record source is selected In the record mode the Ph1 and Ph2 inputs cannot be used at the same time It is not possi ble to listen to Ph2 and record from Ph1 If Ph1 is selected as the record source when Ph2 is the listen source the listen input will change to Ph1 and vice versa NOTE Ten seconds after the last button has been pressed ...

Страница 14: ... display is in the volume mode To select the balance display mode and shift the soundstage to left or right press the BAL L or BAL R buttons If the display is not already showing the balance setting a brief press of either button will select the balance display without changing the setting To centre the balance press the 0 button on the handset when the display is showing the balance setting To se...

Страница 15: ...g sources in turn and for each adjust the vol ume setting so that the same listening level is heard When all adjustments are complete repeat steps 2 and 3 above but note that the message OFFS appears on the display The volume can now be turned up or down to the desired listening level and this level will be maintained for all sources USER SELECTABLE OPTIONS The user can customise operational featu...

Страница 16: ...ection is OFF U9 1 auto listen source selection is ON U10 0 disables the control of the Kairn by a Linn multi room system U10 1 allow the Kairn to be used in the main room of a Linn multi room system U11 0 allows the AUX AUX1 input to be used as a general purpose line level input U11 1 allows the Kairn to be used in conjunction with a surround sound processor U12 0 makes the record source selectio...

Страница 17: ...n to be used in the main room of a Linn multi room system which has Majik amplifiers but on Knekt Room Control Units RCU in the remote rooms The tape record path of the Kairn supplies audio via a Linn Knekt Driver In each remote room the desired source of the main system is selected by choosing the corresponding record input of the Kairn This is achieved by pressing the WHAT button on the Kairn re...

Страница 18: ...commend good quality copper cable for interconnect leads and advise 4mm2 multicore copper cable such as Linn K20 for speaker leads Your Linn dealer can supply high quality interconnects for linking all your hi fi components The Linn KAIRN pre amplifier is designed for a long life and any servicing should be carried out by an authorised dealer Dust or finger marks can be removed by using a soft dry...

Страница 19: ...ed dealers only Unauthorised servicing or dismantling of the product invalidates the manufacturer s warranty If you are in any doubt please contact your nearest Linn dealer For information on your nearest dealer contact the Linn factory in Scotland or your national distributor IMPORTANT Please keep a copy of the sales receipt to establish the purchase date of the product Please ensure that your eq...

Страница 20: ...7nF TUNER CD AUX TAPE INPUTS Sensitivity 188mV rms Load 24 kilohms OUTPUTS TAPE OUTPUTS Tape output auxiliary input level unity gain 1 kilohms output impedance Minimum load 5 kilohms MATRIX OUTPUT For 188mV rms output at 1 kHz 100 ohms output impedance Minimum load 5 kilohms MM Sensitivity 2mV rms MC Sensitivity 130uV rms MAINS SUPPLY FUSE T500MA The same fuse is used for all input voltages POWER ...

Страница 21: ... issue Test type EN55013 2001 Conducted emissions EN55013 2001 Absorbed emissions EN55020 2002 Immunity FCC notice NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses...

Страница 22: ...K A I R N PACK 470 1 KAIRN ENG PLACED 11 27 02 9 27 AM Page 22 ...