Contents
16
Other Stuff - hints and tips.
Linstall V2.00 HELP - with the Linstall software loaded onto your screen hit [ F1 ] for
some useful help information. Look at the [ problem systems ] page for details on
downloading to individual RCU’s from DOS - very useful in an Intersekt system where
one RCU ( three miles away ) won’t download successfully.
For configuring the Intersekt within Linstall have a look in Knektips.doc
Kairn in a Parallel Intersekt System.
Communication between the Main System RCU and the Main System Kairn are via the
Linn Line Remote sockets of Source 1 on the Intersekt. The Main System RCU should be
connected to the RCU RJ45 socket of Room 1 on the Intersekt.
When installing a Kairn in parallel with an Intersekt, you MUST remember to connect the
sources to the Intersekt in the same order as they are connected to the Kairn.
I/P
KairnPhono
KairnPro
1
Phono (mm)
------
2
Phono (mc)
Aux2
3
Tun
Tun
4
CD
CD
5
Aux
Aux1
6
Tape1
Tape1
7
Tape2
Tape2
i.e. A Tuner connected to Input 3 on the Kairn should be connected to Source 3 of the
Intersekt.
Kairn phono.
The phono i/p on a Kairn is available, at Line Level, from the Kairn’s ‘Matrix’ o/p. This
Matrix output should be connected to Source 1 on the Intersekt and set up as...
Type
Aux
Model
IntersektPhono