E1400 V1 Rev. E Installation Guide
6 Description of the connectors / Interfaces
6.1 PE
PE
Protective Earth
PE
•
Use min. 4mm
2
(AWG11)
•
Tightening torque: 2Nm (18 lbin)
6.2 X1-V1 Rev. D/E
X1
DC Busbar/ Regeneration Resistor
RR+:
Positive connection for Regeneration Resistor
RR-:
Negative connection for Regeneration Resistor
DC+:
DC
DC-:
DC busbar -
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm (6.2 – 7.0 lbin)
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.25 – 4 mm
2
(depends on Motor current) / AWG 24 -12
- Stripping length 10mm
6.3 X30-V1 Rev. D/E
X30
Motor Supply Mains
L1 – L3: 3x400 / 3x480VAC 50/60 Hz
PE:
PE, Protective Earth
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm (6.2 – 7.0 lbin)
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 2.5 – 4 mm
2
(depends on Motor current) / AWG 24 -12
- Stripping length 10mm
NTI AG / LinMot
®
www.LinMot.com
Page 9/23