![LinMot E1450-EC-QN-0S Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/linmot/e1450-ec-qn-0s/e1450-ec-qn-0s_installation-manual_1925400019.webp)
E1400 V1 Rev. E Installation Guide
9 Physical Dimensions
E1400 Series
single axis drive
Width
mm (in)
50 (2)
Height
mm (in)
300 (11.8)
Height with fixings
mm (in)
345 (13.6)
Depth
mm (in)
221.5 (8.8)
Weight
kg (lb)
4.3 (9.5)
Mounting
2 x M5, Distance 332 (13.07)
Case
IP
20
Storage Temperature
°C
-25…40
Transport Temperature
°C
-25…70
Operating Temperature
°C
0…40 at rated data
40...50 with power derating
Relative humidity
95% (non-condensing)
Pollution
IEC/EN 60664-1
Pollution degree 2
Site altitude
m amsl
to be defined
Shock resistance (16ms)
-1S option
3.5g
Vibration resistance (10-200Hz)
-1S option
1g
Max. Case Temperature
°C
90
Max. Power Dissipation
W
100
Mounting place
In the control cabinet
Mounting position
Distance between drives
(passive convection cooling)
mm (in)
≥ 35 (1.4) left (heat sink side)
≥ 5 (0.2) right
≥ 200 (8) top / bottom
Distance between drives (with fan
option EV01-E1400)
mm (in)
≥ 40 (1.6) left (heat sink side)
≥ 5 (0.2) right
≥ 200 (8) top / bottom
Distance between drives (cold plate
cooling)
mm (in)
≥ 0 (0) left/right
≥ 200 (8) top / bottom
1 Drive can be mounted upside down (motor connector on bottom side)
NTI AG / LinMot
®
www.LinMot.com
Page 19/23