Installation Guide E1100
Page 12 of 20
Installation Guide E1100 26.01.2006
NTI AG/ LinMot
/
X4: 12pin
Control / Supply (E1130-DP(-HC), E1100-CO(-HC), E1100-DN(-HC), E1100-RS(-HC))
12
11
10
9
8
7
6
5
4
3
2
1
Input
Safety Voltage Enable
I/O
X4.11
I/O
X4.10
I/O
X4.9
I/O
X4.8
I/O
X4.7
I/O
X4.6
I/O
X4.5
I/O
X4.4
I/O
X4.3/Brk
+24VDC Supply
GND
Supply
Power Stage Enable (HW Enable)
Configurable IO, PTC2 Input
Configurable IO, PTC1 Input
Configurable IO
Configurable IO
Configurable IO
Configurable IO, Trigger Input
Configurable IO
Configurable IO, Analog Input
Configurable IO, Brake Driver 1A
Logic Supply 22-26 VDC
Ground
Phoenix
MC1,5/12-STF-
3,5
Inputs
24V / 1mA (Low Level: –0.5 to 5VDC, High Level: 15 to 30VDC)
Outputs
24V / max.100mA
Brake Output
24V / max.1.0A
Supply 24V / typ. 400mA / max. 2.1A (if all outputs “on” with max. load.)
Wiring: 0.25-1.5mm² (AWG24-16)
X4: 11pin
Control / Supply (E1100-GP(-HC))
11
10
9
8
7
6
5
4
3
2
1
I/O
X4.11
I/O
X4.10
I/O
X4.9
I/O
X4.8
I/O
X4.7
I/O
X4.6
I/O
X4.5
I/O
X4.4
I/O
X4.3/Brk
+24VDC Supply
GND
Supply
Configurable IO, PTC2 Input
Configurable IO, PTC1 Input
Configurable IO
Configurable IO
Configurable IO
Configurable IO, Trigger
Configurable IO
Configurable IO, Analog Input
Configurable IO, Brake Driver 1A
Logic Supply 22-26 VDC
Ground
Phoenix
MC1,5/11-STF-
3,5
Inputs
24V / 1mA (Low Level: –0.5 to 5VDC, High Level: 15 to 30VDC)
Outputs
24V / max.100mA
Brake Output
24V / max.1.0A
Supply 24V / typ. 400mA / max. 3.0A (if all outputs “on” with max. load.)
Wiring: 0.25-1.5mm² (AWG24-16)
LED
State Display
Green
Yellow
Yellow
Red
24V Logic Supply OK
Motor Enabled
Warning
Error
S1-3:
Address Selectors / Bus Termination
S2
S1
High
Lo
w
4
3
2
1
on off
S3
S1
S2
S3
Bus ID High
(0…F)
Bus ID Low
(0…F)
Switch 4: Interface on/off (All field bus
interfaces)
Switch 3: Termination CAN on/off
Switch 2: Termination RS485 on/off
Switch 1: RS232 (switch “off” / RS485 “on”)
HEX-Switches for Bus ID (Address
range 0…255)
Factory setting: all switches “off”
Select serial RS232 or RS485
To use field bus functionality the switch S3.4 has to be set to position “on”!
In position “off” the field bus is deactivated.