Page 32 of 62
NTI AG / LinMot
11 Curve Configuration Message Group (not on B1100)
With the Curve Configuration Message Group, curves can be read out or written from/to the drive. For a detailed
description about the saving structure of a curve we recommend [2].
Message Main ID
Message Sub ID
Description
04h
00h
Save Curves from RAM to FLASH. MC SW has to be stopped.
Command has no functionality on C1100.
04h
01h
Delete all Curves in RAM *
04h
02h
Delete Curve in RAM *
04h
04h
Add Curve to RAM * (Define Info Block Size and Data Block Size)
04h
05h
Write Curve Info Block
04h
06h
Write Curve Data Block
04h
08h
Read Curve Info Block Size and Data Block Size
04h
09h
Read Curve Info Block
04h
0Ah
Read Curve Data Block
*
or FLASH on C1100
Request: Save Curves from RAM to FLASH
Byte Offset
Value
Description
0
01h
Fix ID Telegram start
1
11h
Destination node ID
2
03h
Telegram length
3
02h
Fix ID start data
4
00h
Message Sub ID (Save curves from RAM to FLASH)
5
04h
Message Main ID (Curve Message)
6
04h
Fix ID telegram end
Configuration Response: Save Curves from RAM to FLASH
Byte Offset
Value
Description
0
01h
Fix ID Telegram start
1
11h
Destination node ID
2
0Ah
Telegram length
3
02h
Fix ID start data
4
40h
Message Sub ID (Curve Cfg Response)
5
00h
Message Main ID (Response)
6
00h
Communication state (D7h if MC SW not stopped)
7
00h
No meaning (low byte curve ID)
8
00h
No meaning (high byte curve ID)
9
09h
No meaning (response data low word low byte)
10
00h
No meaning (response data low word high byte)