Page 8 of 62
NTI AG / LinMot
3.2 ID and Baud Rate Selection
With the default parametrization the baud rate can be selected over S1 and the ID is selected over S2.
3.2.1 Baud Rate Selection
The baud rate can be defined over the S1 hex switch (default setting) or by parameter value.
S1 Baud Rate Code Table
S1 Value
Selected Baud Rate
0h
Undefined Baud Rate
1h
4800Bit/s
2h
9600 Bit/s
3h
19200 Bit/s
4h
38400 Bit/s
5h
57600 Bit/s
6h
115200 Bit/s
7h
Undefined Baud Rate
8h-Fh
Undefined Baud Rate
3.2.2 ID Selection
Like the baud rate the protocol ID can be defined over the S2 hex switch (default setting), by parameter value or
by the S1&S2 hex switches.
S2 ID code table
S2 Value
Selected MACID
0h
MACID = 00h
1h
MACID = 01h
2h
MACID = 02h
...
...
Fh
MACID = 0Fh
S1&S2 ID code table
S1 Value
S2 Value
Selected MACID
0h
0h
MACID = 00h
0h
1h
MACID = 01h
0h
2h
MACID = 02h
...
...
...
1h
0h
MACID = 10h
...
...
...
Fh
Fh
MACID = FFh