2.3 Additional ATEX safety instructions
Assembly, commissioning, and maintenance of the motors may be performed only by
qualified personnel who are familiar with the directives of DIN EN 60079-14.
Maintenance and service work may be performed only in a clean room with no explosive
atmosphere. Dangerous ignition sources may arise when disassembling component parts.
Only original parts from LinMot may be used for commissioning and maintenance work.
Always make sure that the external ground connection on the motor
is connected to the PE of the machine.
Do not separate when energized.
Operation is allowed only in conjunction with a temperature relay and line protection.
Only for use with an inverter.
The permissible ambient temperature range is 0°
C … +50°C.