3.11 Cabling
The cables must be laid in such a way that they cannot be damaged by external influences.
4 Installation and commissioning
•
The specified power supply to the drive unit must not be exceeded.
•
All intended operating modes of the linear motors must be designed in accordance with
the company's software and verified in application testing.
•
In order to avoid unintended use, the information on the rating plate must be complied
with.
4.1 Operating conditions
•
Maximum ambient temperature limits are 0 °C…50 °C
•
The temperature of the cooling fluid must not fall below the ambient temperature, as this
presents a risk of water condensation. See Paragraph 4.8, Liquid cooling.
•
Internal temperature sensor error occurs at 85 °C or 135 °C
•
The max. installation altitude is 2'000 m (for higher values contact LinMot) above sea
level.
•
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
Temperature relay
Length (KTY-cable) = 460 mm
LinMot Servo Drive
Trailing Chain Cable
KS10-EX-Y-Fe/E6k-
EX Linear motor