20
Appendix A:
RPS1000—Business Series 380W RPS Unit Installation & Administration
Appendix
A
Technical Specifications
The following table lists the technical specifications for the RPS1000.
Environmental Ranges
Operating temperature
32 to 113°F (0 to 45°C)
Storage temperature
–4 to 149°F (–20 to 65°C)
Operating humidity
10 to 85% (noncondensing)
Storage humidity
5 to 95% (noncondensing)
Operating altitude
Up to 10,000 ft (3,000 m)
Storage altitude
Up to 15,000 ft (4,570 m)
Power Requirements
AC input voltage
100 to 240 VAC (auto ranging)
6 to 10 A, 50 to 60 Hz
875 W
Power delivery (available
power) Total
375 W per –48 VDC output and
300 W per 12 VDC output
Standby power
25 W
KVA
0.875 KVA
Physical Dimensions
Weight
11.5 lb. (5.22 kg)
Dimensions (H x W x D)
1.75 x 17.5 x 14.88 in.
(4.45 x 44.45 x 37.8
cm)
Safety
EMC
UL 60950
FCC Part 15 Class A
CAN/CSA 22.2 No. 60950
BSMI
IEC 60950/EN 60950
EN 55022: 1998 (CISPR22) Class A