Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2011 – Linkcom – All rights reserved
18
x=1 : ON
WRITE ALARMON
+420cc..c
Savings of number for SMS « ALARM ON » (input grounding)
WRITE ALARMOFF
+420cc..c
Savings of number for SMS « ALARM OFF »
(input disconnection)
CAL AT+CSQ
Signal strength level
CAL AT+CPBR=x
Info about number saved on position x
CAL
AT+C
̌
CLK= <time>
Setup time in GDI <time>
Format <time>= yy/MM/dd,hh:mm:ss±zz
yy – year (00-99)
MM – month (01-12)
dd – day (01-31)
hh – hours (00-23)
mm – minutes (00 – 59)
ss – seconds (00 – 59)
±zz – time zone (-47..+48) hours
5.1. Command types:
READ
– command to read the parameters.
CLR
– command to erase phone numbers from SIM card.
CAUTION
!
When you use SMS for numbers erasing then don’t forget that one ADMINx number
must stayed! Otherwise remote settings will not be possible (necessary to make new initialization).
INIT
– Initialization. During the first setting when SIM doesn’t includes any ADMINx number, it is
necessary to put such number on the SIM card. It is done by SMS with INIT command. The SMS can be
sent from any number. When SIM card already has at least one number with name ADMINx the
command is ignored.
WRITE
– command to save the parameters.
CAL
–
after command CAL, you can put any « AT command » used by the GSM module (for example:
module reset, time setting etc.).
Those commands please use with appropriate knowledge only! It can
cause blocking of whole unit!