background image

 

 

4

 

                                  

 

2.1.2 Uncover control elements 

4. 

Push the aluminium speaker grille down (see figure – 4). 
 

 

 
 

 
 
 
 

2.1.3 Wiring and wall mounting 

5. 

Use the wall mounting template at the end of the 
manual to mark the position for the screw holes and 
cable connection on the mounting surface. Drill the 
holes. 

        6.  

Feed the cable (analogue  line, power supply, lock – 
see figure - 6) through the cable hole. 
Fix the panel to the wall using the screws and rawlplugs 
supplied. 

 

 Note:

 

Some materials such as metal and wood may 

require special screw types.

  

 
To power the unit for voice, connect the telephone wires 

into the terminal (on the right side). Using either a 
standard analogue phone line or an analogue extension 
on a PBX. 

For the external power supply, connect to the terminal "

12V

" external power supply AC min. 10V / 

max. 15V or DC min. 12V / max. 18V.  

The energy consumption of a connected electrical (magnetic) lock (0,5A – 1,0A) determines the load 

on the power supply. If you activate the heating feature the PCB current will climb to about 150mA. 
We recommend power supply AC 12V/1A. 

 
 
The wiring of relay contacts is explained in the next picture. The symbol "

NO

" means contact 

normally open, "

COM

" means sharing output  

(central) and "

NC

" means contact normally closed. The relay contact is isolated from the other 

circuits on the board. For the variants of lock connection see the picture below. 

  

  

 
 
 
 
 
 
 
 

 
 
 

 
Wiring of standard and magnetic (inverse) lock  

 

6. 

A special USB cable enables the doorphone to be connected to a PC for programming of 
individual parameters. A dedicated Windows program is included on the CD (requires version 
W98SE or higher).  

 

Power 
supply 

lock 

Telephone 
line

Содержание Door phone

Страница 1: ...Doorphone Link Slim Door Phone User Guide for Link Slim Door phone...

Страница 2: ...IGNALLING OVERVIEW 8 3 2 VISITOR AT THE DOOR 8 3 3 TELEPHONE CALLER 8 3 3 1 Outgoing call 8 3 3 2 Incoming call 9 4 PARAMETER PROGRAMMING 9 4 1 PROGRAMMING FROM A TELEPHONE BY DTMF 9 4 1 1 Entering pr...

Страница 3: ...MF tones Recall and Pause duration 3 default levels Programming by remote control DTMF and by direct PC connection via USB cable available separately Integrated heating of printed circuit PCB option P...

Страница 4: ...r supply connect to the terminal 12V external power supply AC min 10V max 15V or DC min 12V max 18V The energy consumption of a connected electrical magnetic lock 0 5A 1 0A determines the load on the...

Страница 5: ...gned for loudspeaker volume setting The volume settings are more than adequate for most situations Therefore we do not recommend setting the trimmer position more than The most suitable position is 1...

Страница 6: ...aluminium grille PC connector SlimDoorPhone fixing screw hole Service switch Loudspeaker MIC setting of microphone volume TRH setting of microphone activation level SPK setting of speaker volume Heati...

Страница 7: ...ID Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gently pressed if requi...

Страница 8: ...first press the number set in parameter 1 will be dialled By pressing of the same button twice or on detection of busy tone after trying the first number the unit will select the number from the secon...

Страница 9: ...initial state for programming is signalled by the programming confirmation tone The unit will always revert to this state after 5 seconds of inactivity even if you have started to program a parameter...

Страница 10: ...sconnect the USB cable from unit and connect it again The unit will answer and providing the ID Manager program is running it will confirm its entry into programming mode again Refer to the ID Manager...

Страница 11: ...uttons 2 to 6 digits The 3 passwords are controlled by Day Night the combination is entered using the unit buttons It is influenced by the setting of Relay mode and Day Night switchover When set to 2...

Страница 12: ...m 1 Exam 2 44 xxxx Password 0000 0000 0000 xxxx service password for entry to programming Parameter Value Description Default Exam 1 Exam 2 45 dd DAY MODE switching 11 11 11 46 nn NIGHT MODE switching...

Страница 13: ...This time is different for each PBX but most PBXs usually manage to process dialling up to 2 seconds after line on hook Parameter Value Description Default Exam 1 Exam 2 56 h Number of rings before ha...

Страница 14: ...ang up If you hang up the phone during programming mode without press 9 the doorphone will stay in programming mode during 20 seconds 5 7 System setting Parameter Value Description Default Exam 1 Exam...

Страница 15: ...mode 1 1 2 32 hhhhhh External access code in DAY NIGHT mode 2211 1324 33 hhhhhh External access code in DAY mode 2211 2211 34 hhhhhh External access code in NIGHT mode 1122 1122 35 aa Internal access...

Страница 16: ...ltage 18V line hang up Voltage on line while off hook VA characteristics 8V 12V I 20mA I 60 mA Leakage in hang up status 50uA U 60V Impedance of line termination 130R 820R paral 220n line answered Ban...

Страница 17: ...under button 3 Night Gr 2 203 16 Number under button 4 Night Gr 2 204 16 Relay mode m 1 2 31 1 External access code Day Night 32 6 External access code Day 33 6 External access code Night 34 6 Intern...

Страница 18: ...18 8 Drilling master board...

Отзывы: