3 SlimDoorPhone Services 

3.1 Signalling Overview 

The unit signals acoustic conditions that may occur during operation. You can listen to the signalling 

samples in the ID Manager program. 

 

Condition Tones 

Tone 

frequency

Pick up line 

– 425-850-1275 

Hang up line 

 1275-850-425 

Confirm command 

––

–– 425 

Dialling DTMF/Pulse 

 

Call  

 

Conversation end warning 

– 1275 

Enter programming (phone or PC) 

– 850 

Programming tone 

––

––––– mod. 

850 

Parameter confirmation  

––

––  

Programming from PC 

Silent 

 

Connection to line (Reset) 

– 1275-850-1275 

Error 

– 

425…. 

Empty memory 

– 

850-1275-1700… 

Open lock 

▓▓▓▓▓▓▓

 

modul 50/1250 

3.2  Visitor at the door 

When a visitor presses a button the unit will lift up the line, either immediately (providing the button is 

not the first number from code lock), or with delay (

parameter 53) 

and after period given by 

parameter 55,

 

will dial the programmed phone number. The dialled number is dictated by the chosen mode, which is set 
in the unit (

parameter 47

): 

Day/night

 

mode

 = If the unit is in Day mode, it will always dial the number set in 

parameter 1

, In 

Night mode, it will always dial the number set in 

parameter 2

. The mode switchover is set in 

parameters 45,46

Two-Group mode

 = on the first press the number set in 

parameter 1 

will be dialled. By pressing of 

the same button twice, or on detection of busy tone after trying the first number, the unit will select 
the number from the second group (

parameter 2

). The next press of the same button again selects 

the number from the first group, etc..…… 

If the button is pressed after the line has been opened (but before the call is answered), the unit will 

hang up for the period given by 

parameter 54, 

lift up the line and dial the other group number.  

The relay can be controlled by pressing the buttons in the combination that is set in the 

preprogrammed code (

parameters 32-34

). The time between presses must not be bigger than that set in 

parameter 53.

 The unit will lift up and close the corresponding relay or the period given by 

parameter 36 

Then it will hang up. 

3.3 Telephone Caller 

A Telephone Caller is a person that is in phone connection with SlimDoorPhone. 

3.3.1 Outgoing call 

An “outgoing” call is a call from the unit (i.e. when a visitor presses a button). Once the visitor has 

pressed a button a telephone will ring. On answering the telephone, you will be able to converse with the 
visitor. 10 seconds before the maximum call duration (

parameter 52

) the unit will emit a tone to warn that 

the call will end. The call may be extended by pressing the key as set in 

parameter 42

. A code may be 

Содержание Door phone

Страница 1: ...Doorphone Link Slim Door Phone User Guide for Link Slim Door phone...

Страница 2: ...IGNALLING OVERVIEW 8 3 2 VISITOR AT THE DOOR 8 3 3 TELEPHONE CALLER 8 3 3 1 Outgoing call 8 3 3 2 Incoming call 9 4 PARAMETER PROGRAMMING 9 4 1 PROGRAMMING FROM A TELEPHONE BY DTMF 9 4 1 1 Entering pr...

Страница 3: ...MF tones Recall and Pause duration 3 default levels Programming by remote control DTMF and by direct PC connection via USB cable available separately Integrated heating of printed circuit PCB option P...

Страница 4: ...r supply connect to the terminal 12V external power supply AC min 10V max 15V or DC min 12V max 18V The energy consumption of a connected electrical magnetic lock 0 5A 1 0A determines the load on the...

Страница 5: ...gned for loudspeaker volume setting The volume settings are more than adequate for most situations Therefore we do not recommend setting the trimmer position more than The most suitable position is 1...

Страница 6: ...aluminium grille PC connector SlimDoorPhone fixing screw hole Service switch Loudspeaker MIC setting of microphone volume TRH setting of microphone activation level SPK setting of speaker volume Heati...

Страница 7: ...ID Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gently pressed if requi...

Страница 8: ...first press the number set in parameter 1 will be dialled By pressing of the same button twice or on detection of busy tone after trying the first number the unit will select the number from the secon...

Страница 9: ...initial state for programming is signalled by the programming confirmation tone The unit will always revert to this state after 5 seconds of inactivity even if you have started to program a parameter...

Страница 10: ...sconnect the USB cable from unit and connect it again The unit will answer and providing the ID Manager program is running it will confirm its entry into programming mode again Refer to the ID Manager...

Страница 11: ...uttons 2 to 6 digits The 3 passwords are controlled by Day Night the combination is entered using the unit buttons It is influenced by the setting of Relay mode and Day Night switchover When set to 2...

Страница 12: ...m 1 Exam 2 44 xxxx Password 0000 0000 0000 xxxx service password for entry to programming Parameter Value Description Default Exam 1 Exam 2 45 dd DAY MODE switching 11 11 11 46 nn NIGHT MODE switching...

Страница 13: ...This time is different for each PBX but most PBXs usually manage to process dialling up to 2 seconds after line on hook Parameter Value Description Default Exam 1 Exam 2 56 h Number of rings before ha...

Страница 14: ...ang up If you hang up the phone during programming mode without press 9 the doorphone will stay in programming mode during 20 seconds 5 7 System setting Parameter Value Description Default Exam 1 Exam...

Страница 15: ...mode 1 1 2 32 hhhhhh External access code in DAY NIGHT mode 2211 1324 33 hhhhhh External access code in DAY mode 2211 2211 34 hhhhhh External access code in NIGHT mode 1122 1122 35 aa Internal access...

Страница 16: ...ltage 18V line hang up Voltage on line while off hook VA characteristics 8V 12V I 20mA I 60 mA Leakage in hang up status 50uA U 60V Impedance of line termination 130R 820R paral 220n line answered Ban...

Страница 17: ...under button 3 Night Gr 2 203 16 Number under button 4 Night Gr 2 204 16 Relay mode m 1 2 31 1 External access code Day Night 32 6 External access code Day 33 6 External access code Night 34 6 Intern...

Страница 18: ...18 8 Drilling master board...

Отзывы: