Enabling/Disabling a Sensor
Menu->SystemSetup->SensorSetup->button 1 Basic->Sensor Mod (Enable/Disable) Outdoor Sensor
(Enable/Disable)
Wiring Equipment on the Low Voltage Outputs
The iPonic
TM
614 has two (outputs 7 and 8) relays that are provided as dry contacts, i.e. “switch closures.
If an output is activated to ON, the switch is “closed” (shorted); and if it is activated to OFF, the switch is
“open” (no continuity between the positive and negative terminals).
The board mounted relays are intended as “pilot” relays. For most loads you will want the iPonic 600™
outputs to control a load relay or contactor that is connected to the motor. However, in some cases such
as and alarm unit or irrigation valves that are 24 VAC, you can drive them directly assuming that you are
wiring only one or two valves per relay. The maximum current load recommended for each of the iPonic
600™ relays is 1.0 amp.
Warning – Do not exceed 1 Ampere or 24 Volts for outputs 7 and 8
Figure 2.3 Low Voltage Connection Points for Outputs 7 and 8.
Programming Equipment to the Low Voltage Outputs
By default you can program only the first 6 outputs for which outlets are provided. If you wire additional
equipment to either of the last two relays (as described above) you will need to program this additional
equipment into the controller. An advanced setting will allow you to choose any of the 8 outputs (including
the unnamed relays) and set the type of the equipment the controller will recognize as being installed at
that output.