11
directly into outlet 5 (output 4) of the iPonic
TM
614 controller so long as the total amperage drawn by all
equipment on the iPonic
TM
614 does not exceed 15 amps.
Humidifier Setup
If you wish to control a humidifier with the iPonic
TM
614 make sure the equipment is selected using the
Equipment Selection procedure at the beginning of this chapter. When choosing to control an air
conditioner you must first deselect another piece of equipment. The humidifier will take the place of the
disabled equipment type. Refer back to Figure 1.0 at the beginning of this chapter to determine which
outlet to plug your humidifier into. This equipment type can be plugged directly into the iPonic
TM
614
controller so long as the total amperage drawn by all equipment on the iPonic
TM
614 does not exceed 15
amps.
Humidity Setpoints
With the iPonic
TM
614 you can keep the humidity level of your hydroponic facility within your own specified
normal range. To do this, you will need to program a dehumidifying target called a “DeHum Setpoint” and
a humidifying target called a “Hum Setpoint”. The humidity range between these two targets is called the
“Normal” humidity range. If the measured humidity is within the normal humidity band, the dehumidifying
and humidifying equipment will be turned off.
To Change the Humidifying and Dehumidifying Setpoints
From the home screen of your iPonic
TM
614, press the menu button. Select option 1, “Current Setpoints”
and press OK. Select option 2, “Humidity Setpoint” with the wheel and press OK. Press button 4 on the
user interface to choose the time setpoint period you want to adjust the humidifying and dehumidifying
setpoints for. Press button 5 to change the lower of the two values known as the Humidify Setpoint. Use
the wheel to adjust the humidity setpoint by an increment of 1% or you can press button 1 to change this
increment to 10% and then use the wheel to change the humidity setpoint. Press OK. Press button 6 to
change the higher of the two values known as the Dehumidify Setpoint. When you are done making
changes to the cooling and heating setpoints, press OK. Press OK again to confirm your changes.
Irrigation
Irrigation Pump Setup
If you wish to control the irrigation pump in your facility with the iPonic
TM
614 make sure the equipment is
selected using the Equipment Selection procedure at the beginning of this chapter. Assuming a small
(less than two amperes) irrigation pump for your output, this equipment type can be plugged directly into
outlets 3 & 4 (output 3) of the iPonic
TM
614 controller so long as the total amperage drawn by all
equipment on the iPonic
TM
614 does not exceed 15 amps.
Irrigation Settings
From the home screen of your iPonic
TM
614, press button 3 which corresponds with the output for “Irrig
Pump”. Select “Settings” using the wheel and press OK. Press button one to enable the irrigation pump.
To adjust the start time of your irrigation cycle press button 5 on the user interface. Use the buttons and
wheel on the user interface to set the start time for your irrigation cycle. Press OK when you have
selected the correct time. Press OK again to save your changes. Press button 6 on the Irrigation Settings
screen to set the irrigation cycle end time in the same way. Press button 7 on the Irrigation Settings
screen to set the On Period to set the amount of time you would like the irrigation pump to run during
each phase of the cycle to set the On Period length. Press button 8 on the Irrigation Settings screen to
set the Off Period to set the amount of time you would like the irrigation pump to run during each phase of
the cycle to set the Off Period length. When you are done making changes press OK. Press OK again to
save your changes.