960-3100-00
iPonic 614 Installation Manual
8
numbers on the sides of the controller show which outlets are connected to each output. If no humidifier
or air conditioner is part of your setup then the outputs and outlets will be configured as shown in
Figure
1.0
. Any of these equipment types can be replaced with a humidifier or an air conditioner. If you choose to
do this, the humidifier or air conditioner will take the place of the output and outlets of the unused
equipment type.
Output Equipment
Outlets
1
Lights
1
2
CO
2
Injector
2
3
Irrigation Pump(s)
3
4
4
Dehumidifier
5
5
Heater
6
6
Vent Fan(s)
7
8
Figure 1.0 Default Equipment Outputs
Time Setpoints
By default you have two time setpoints, one for day and one for night. This default Day Setpoint begins at
5:00 am, with a Normal temperature target range between 75ºF and 78ºF. The humidity target range is
between 40% and 60%. The CO
2
target is 800 ppm and the lighting equipment is on to facilitate
photosynthesis. The default Night Setpoint begins at 11:00 pm, with a Normal temperature target range
between 65ºF and 85ºF. The humidity target range is between 40% and 60%. The CO
2
target is 0 ppm
and the lighting equipment is off. See
Figure 1.1
to view these defaults in table form.
These setpoints tell the controller how to control the hydroponic environment (the light, temperature,
humidity and CO
2
level) based on the time of day. During a time setpoint, the controller will activate the
necessary equipment during heating and cooling stages to bring the environment back to the normal
range for that time setpoint. A humidify and dehumidify setpoint can be set for each of your time setpoints
which will activate installed equipment when the humidity falls below the humidify setpoint or rises above
the dehumidify setpoint. The same applies when the CO
2
level falls below the target for that time setpoint.
The time setpoint will also determine whether any installed lighting equipment is on or off for the duration
of the setpoint. The only basic control that runs independently of these time setpoints is irrigation. For
each time setpoint there is a programmable “Start Time” and each time setpoint ends at the “Start Time”
of the next setpoint. You will be able to use up to 3 time setpoints in a 24 hour time period.
Setpoint
Start Time
Temperature
Humidity
CO
2
Light
Low
High
Low
High
DAY
5:00 AM 75.0ºF (23.9ºC) 78.0ºF (25.6ºC)
40%
60%
800 ppm ON
NIGHT
11:00 PM 65.0ºF (18.3ºC) 85.0ºF (29.4ºC)
40%
60%
0 ppm OFF
Figure 1.1 Default Time Setpoints and Settings
Changing Day/Night Setpoints
You can adjust the time and duration of your day and night time setpoints. From the home screen of your
iPonic
TM
614, press the menu button. Select option 1, “Current Setpoints” and press OK. Select option 5,
“Setpoint Times” with the wheel and press OK. To adjust the start time of your Day time setpoint press button 2
on the user interface. Use the buttons and wheel on the user interface to set the start time for your Day time
setpoint. Press OK when you have selected the correct time. Press OK again to save your changes. To adjust
the start time of your Night time setpoint (the end of your Day time setpoint) press button 3 from the Setpoint
Times screen and adjust this time in the same way.