5
268 280
19
268 280
19
R4
R4
Flügel
Rahmen
6
M 13 85
Installation in tubular frame doors
Processing of frame / leaf
• Mill long slot width 20 mm and length 268 mm,
corner radius max. 4 mm (28 mm deep)
• Pre-drill for forend screw 2x
• Cables are run through the profile
3.1 General notes on assembly
Due to the plurality of profiles and fittings available on the market, no
general information for mounting can be given since these systems
differ in several dimensions. Please check the place of installation and
the space available in the rabbet and profile area before the beginning
of assembly.
• Place of assembly: Door rabbet
• Minimum installation depth M 13 85 / 86 : 28 mm
• Minimum installation depth M 13 25 / 26 : 50 mm
• The place of installation should be chosen in such a way that the
coil is not crushed when the door is closed
• The SmartLINK must be installed in a U-shape (see Fig.)
• In addition to the generally valid state of the art, the following tech-
nical codes are to be particularly observed:
DIN VDE 0100, VdS 2311
3 | Assembly
max. 180°
max. 90mm
max. 90m
m
M 13 85 / M 13 86
M 13 85
Leaf