Custom Configuration Commands:
The PJ7 interface has an internal USB based configuration serial port to enable customization of
settings. The settings are volatile and default to factory defaults when power is interrupted. The
purpose of the commands is to allow the CAD software to make custom changes to the PJ7 based
on the logged on operator therefore defaults are overwritten by the CAD software when it starts.
If necessary Link can default purchased units to contain the customers preferred settings on
power-up, contact Link Communications for details.
Serial Port:
Baud:
19,200
Handshaking: None
Stop Bits:
One
Parity:
None
Refer to your Device Manager for the correct COM port the reference
Commands:
To make sure you are communicating out the correct COM port, hit the ENTER key and you
should get the “PJ7>” prompt on the screen.
To enter a serial command start with an open-bracket ‘[ ‘ followed by the command number and
terminated with a closed-bracket ‘]’.
For example, I want to see what the settings are, so I enter the interrogate command ‘0': [0]
The result appears:
PJ7>[0]-----------------------------------------
PJ7 Microphone Level: 005
Hand Microphone Level: 010
Volume Configuration: X=0:Y=0:Z=0
Initial Volume Level for PJ7 Headphones: 128
Initial Volume Level for Line Out: 128
Lower Limit for Headphone Audio: 005
Upper Limit for Headphone Audio: 250
Lower Limit for Line Out Audio: 005
Upper Limit for Line Out Audio: 250
-----------------------------------------