Link XP L2102/L2104 Receiver Instruction Manual Issue 1 - October 2003 Page 8 of 48
Link Research Ltd. 23/24 Watford Metro Centre, Dwight Road, Watford, Hertfordshire, WD18 9XA, England. Tel: +44 (0) 1923 200 900
Registered in London No. 2074604
Web:
www.linkres.co.uk Fax: +44 (0) 1923 241 357
L2102 & L2104 Receiver
Instruction Manual
Figure 2 – L2102 rear panel connections AC powered
ASI out
Remote/Alarm/Data
VIDEO
SDI
RF1
RF2
100/240V
50/60Hz
1A ~
FUSE
T1.6A
240V
RF3
RF4
F/LOCK
AUDIO 1
AUDIO 2
Figure 3 – L2104 rear panel connections AC powered
Connector type
Legend
Description
F-type 75
Ω
threaded
socket
RF1 & RF2
RF3 & RF4
RF input from L3010 down convertor
Power output for L3010
22kHz tone output for control of L3010
9-way D-sub socket
Remote/Alarm/Data
RS232 remote control port
Alarm signalling, firmware upgrade
BNC 75
Ω
bayonet
socket
ASI out
ASI transport stream output
BNC 75
Ω
bayonet
socket
Video Video
output
BNC 75
Ω
bayonet
socket
Frame lock
Delays the output signal by up to 40ms
to lock the video frames to an external
reference.
NB – colour sub carrier is not locked.
BNC 75
Ω
bayonet
socket
SDI SDI
output.
5-way XLR
Audio 1 & Audio 2
Two audio stereo pairs or 4 mono
channels outputs or 2 digital audio
outputs
IEC socket*
Mains 110 –220VAC
Mains power input
4-way XLR panel
mounted plug*
DC in
DC power input 9VDC – 32VDC
* Standard configuration is for IEC mains input. The DC input is optional and replaces the
IEC socket.