background image

Interface Converter

Instruction Manual

16 th

The CD-ROM attached to a product contains the newest English and Japanese 

instruction manuals in a PDF format. Please also refer to them.

LAN 

 RS-232C 

  SI-60F

LAN 

 RS-232C 

  SI-60

LAN 

 RS-422/485    SI-65

Содержание SI-60

Страница 1: ...Instruction Manual 16 th The CD ROM attached to a product contains the newest English and Japanese instruction manuals in a PDF format Please also refer to them LAN RS 232C SI 60F LAN RS 232C SI 60 L...

Страница 2: ...ve any questions feel free to direct your inquiries to LINEEYE LINEEYE makes no warranty or guarantee either expressed or implied with respect to its quality performance merchantability or fitness for...

Страница 3: ...und emanates from itself Continuous use may cause a burn fire or electric shock Keep the products dry Keep them away from water Failure to do so may cause overheating an electric shock or unit malfunc...

Страница 4: ...y damaging a cord Please do not damage the power cable by pulling stamping or tearing This may result in a injury an electric shock fire explosion and or a breakdown due to overheating Do not place th...

Страница 5: ...sic Configuring Tasks 18 5 1 Connection to the Networok 18 5 2 Basic Set Up Tasks 18 5 3 IPAddress Assignment 19 5 4 DeviceInstaller Usage 19 5 5 Check IPAddress 20 5 6 Assign IPAddress 21 Chapter 6 C...

Страница 6: ...or 2 Flow Control Xon off RTS CTS Xon off Line monitoring LED Display SD RD SD RD RS CS 6 20 SD SD RD DRIVER ACTIVE Surge Protection 15KV ESD L A N Interface Ethernet IEEE802 3 RJ 45 connector 10BASE...

Страница 7: ...ued by Lantronix To learn more detail about the contents read README_E TXT on the root folder of CD ROM 1 5 Option We provide the following optional goods RS 232C cable SI RS259 RS 422 cable SI C422 T...

Страница 8: ...Jack Is a socket to connect to the AC adapter 2 4 SI 60F Power Source 4 Ethernet Connector Ethernet IEEE802 3 RJ 45connector 10Base T 100Base TX auto detection available 9 5 LAN Connector Specificati...

Страница 9: ...emale to connect e g 3 Connecting the AUX port Mini DIN8 pin female of analyzers LE 8200 35 00 2500 7200 3200 2200 1200 to SI 60F Use LE2 8V cable to connect LE2 8V cable is an optional cable 2 4 SI 6...

Страница 10: ...Since the slide switch on the converter is designed for DTE DCE switchable any devices can be connected to the RS 232C side The following chart shows the internal structure of the converter LAN XPort...

Страница 11: ...or Specification 6 RS 232C Connector Dsub25 pin Female M2 6 mm Screw RS 232C Connector Pin Assignment Pin No 1 Name I O Direction 2 Description DTE DCE 1 FG Frame Grand 2 SD Out In Transmission Data 3...

Страница 12: ...ct the AUX port Mini DIN8 pin female of analyzers LE 8200 3500 2500 7200 3200 2200 1200 to SI 60 Set DTE DCE switch to DTE 3 4 SI 60 Power Source Supply power to the converter in either of two ways Su...

Страница 13: ...duct the flow control To use this function the flow control of built in XPort is required to set to CTS RTS Hardware RS 485 Line Condition Flow Control Condition The period of time from when to detect...

Страница 14: ...ess to screw type Standard Torque 0 25Nm M3 4 4 SI 65 cable connection 1 Press down the DIP switch to switch on and press up to switch off 6 Pole Terminal Block Pin Assignment for RS 422 485 Terminal...

Страница 15: ...timer is accurate at 10 to 10 SW A No 4 Driver Control Selects two kinds of control methods in the RS 422 485 driver control line of the converter active and auto SW A Meaning OFF ON No 4 RS 422 485...

Страница 16: ...SD RD and SD RD terminals SW B No 2 Echo Back Setup Selects the echo back specification for the half duplex RS 485 mode OFF Echo Back Echo back the data which is sent from the converter to the RS 485...

Страница 17: ...owing are the recommendation Phoenix Contact Inc AI0 25 8YE AWG24 JST Mfg Co Ltd TUB 05 AWG26 22 Send and Recive DataB Send and Recive DataA GND SG SD SD SD RD SD RD GND SI 65 Target Device RS 485 hal...

Страница 18: ...r the optional AC adapter into the AC adapter plug on the converter The AC adapter of Japanese model is for the use in Japan only Please do not exceed the input voltage rate To use the products abroad...

Страница 19: ...nection to configure the unit over the network or use a terminal or terminal emulation program to access the serial port locally IF you configure the unit through a serial connection reset the XPort u...

Страница 20: ...starting XPort operation And it uses the ARP request to check whether or not any devices on the network use the address If it is not used the address will be used as the XPort address If it is used XP...

Страница 21: ...depending on when you bought this product Please refer Release txt in the folder of the name of the version in the CD ROM attached to the product CD ROM lantronix DeviceInstaller for the detail of Net...

Страница 22: ...cannot detect SI 60F SI 60 SI 65 even if DHCP BOOTP or both are effective 4 XPort restart by pressing Assign button on the Assignment page IP address can also be assigned using Setup mode and SILANIOi...

Страница 23: ...t menu to display DeviceInstaller window Select the device being set Select Web Configuration tab and click icon Enter the user name and the password as you will be required If you have not set your u...

Страница 24: ...Clicking the OK button tells the XPort what changes to use the Apply Settings button makes the changes permanent and reboots the XPort Set the setting of IE Select Tool Internet Options Temporary Int...

Страница 25: ...Flow Control to be same as the target device 3 Click OK and then click Apply Settings 6 3 Set up LAN connection mode LAN protocol Select Channel 1 Connection Then select TCP or UDP You can setup eith...

Страница 26: ...Send Frame Immediate No Send Trailing Bytes Two If the packet size reaches to the Maximum Transmission Unit MTU default 1400 bytes a transmission might occur even if the packets are not satisfy the c...

Страница 27: ...F please refer following setting Example of DeviceInstaller Setting Assign by the proper method concerning the usage and environments and consulting with your network manager Example of Web Manager Se...

Страница 28: ...ing Example of Web Manager Setting SerialPort Condition LANConnection Mode Server Mode Disable ClientMode Enable Assign by the proper method concerning the usage and environments and consulting with y...

Страница 29: ...bit Parity even Stop bit 1bit Flow Control RTS CTS Example of DeviceInstaller Setting SI60 65 60F 1 SI60 65 60F 2 Assign by the proper method concerning the usage and environments and consulting with...

Страница 30: ...eives data the device which received the data will connect with the other device by TCP and send the data through the network Note Like this example communication will be done without errors though th...

Страница 31: ...o PCs which have already installed such software Note 8 2 SI60 65 60F Basic Setting Depending on the target devices setup of the serial port and virtual COM port condition is required to change 6 2 Co...

Страница 32: ...box check the COM port you wish to use as the virtual COM port 4 In the Settings tab there is a host list table Set the IP address and port number at Host and TCP Port in the Service1 Click Search Fo...

Страница 33: ...etwork at the time of starting XPort operation AutoIP Function When AutoIP function is valid and there is no DHCP server on the network XPort selects an IP address within the class B subnet 169 254 x...

Страница 34: ...Stop 1bit Flow Control None LAN Action Mode Accept Incoming Yes Server ModeEnable Active Connect None ClientModeDisable Port No 10001 IP Address0 0 0 0 DHCP Client Function and AutoIP Function Enable...

Страница 35: ...IOinitXXX folder XXX would be the version of SILANIOinit in the utility CD to the appropriate folder For example c setup 2 Set your device in the same network segment as your PC If your devices are no...

Страница 36: ...2 5 will appear Click Next 7 Device upgrade wizard step 3 5 will appear Select Install setup records from a file and click Browse 8 Open the configuration file in the appropriate folder For example c...

Страница 37: ...ws the result Command 1Bh 02h 00h 00h 00h xxh 00h 00h 00h 00h 9byte Response 1Bh xxh 00h 00h 00h 5byte xxh bit 1 0 Specify RS 422 485 driver is acrive as factory setting xxh bit 1 1 Specify RS 422 485...

Страница 38: ...I 60F LAN Connecter AC Adaputer plug SI 60 SI 65 LAN Connecter AC Adaputer plug To fix the converter screw the screws within 7mm in the surface of the bottom case When you screw the screws deeper than...

Страница 39: ...AN cable which meets specification of the LAN connector for the target devices Cannot find in the Deviceinstaller Is SI 60 65 60F connected to the same network segment with PC Can not serach if SI 60...

Страница 40: ...s and conduct the proper setup Is the communication condition set correctly Set to the same values the communication speed data bits parity stop bits flow control etc on both the converter and target...

Страница 41: ...ical stress misuses abuse negligence or accidents LINEEYE disclaims all other warranties including the warranties of merchantability fitness for some particular purposes and noninfringement of third p...

Страница 42: ...rahasi Nishihiragaki cho Minami ku Kyoto 601 8468 Japan TEL 075 693 0161 FAX 075 693 0163 Technical Center 8 49 Kouen cho Nagahama Shiga 526 0065 TEL 0749 63 7762 FAX 0749 63 4489 URL http www lineeye...

Отзывы: