VMC1MB Installation
Pull Wires
•
Pull all the Door and Room station cables to the location of the Master Station (VMC1MB)
•
Connect to Terminal Block (See Figure 3)
The VMC1 Rough In Kit includes an eight position terminal block for ease of installation. For all Door Stations and Home-Run Room Stations, the
majority of the wires will be connected to this Terminal Block. Before installing the terminal block, Linear recommends pre-wiring and then firmly
attach the terminal block to an available wood stud within 12 inches of the Master Unit location.
No more then 5 room stations should connect to a single terminal block that is then connected to the Master Unit. If the installation consists of
more
than
5 room stations, Linear recommends using the optional Linear H628 (8 stations) or DMD-16(16 stations) Data Distribution module.
The recommended wire color convention is recommended:
Table 5
Position
Video Door Station
Room Station
NON Video Door Stations
1
Green White
Green White
Green White
2
Green
Green
Green
3
Orange White
Orange White
Orange White
4
Orange
Orange
Orange
5
Blue White
Blue White
Blue White
6
Blue
Blue
Blue
7
Connect to Master
Brown White
not used
8
Connect to Master
Brown
not used
Figure 3
FROM
DOOR
STATION
FROM
ROOM
STATION
FROM
NIGHTSTAND
STATION
FROM
ROOM
STATION
FROM
ROOM
STATION
CAT5 to Master Station
MATCH
WIRE COLORS
ON EACH TERMINAL
USE TERMINAL BLOCK TO COMBINE CAT-5 CABLES FROM STATIONS
8-POSITION
TERMINAL
BLOCK
GRN/WHT GRN ORG/WHT ORG BLU/WHT BLU BRN/WHT BRN
USE WOOD SCREWS
TO SECURE TERMINAL
BLOCK TO STRUCTURE
13
Содержание M&S VMC1
Страница 26: ...26...