DOOR RELEASE Rough In
The Door Release Trigger can be activated from the VMC1 Master or any remote room station by pressing the Lock button. The Trigger will deactivate
after 4 seconds and can be activated multiple times while the intercom is active.
To connect the optional Linear Model DRW Door Release Mechanism, refer to be instructions below. For controlling other door release devices, refer
to the hook-up instructions supplied with the device.
Door Station Rough In
1. Route a blue and a white 18 gauge wire from the Door Station location or VMC1MB to the optional 12V mini-relay (See Appendix A). Following
this color convention will assist in the final installation of the Door Station.
2. Connect the blue wire to the positive (+) terminal on the optional mini-relay.
3. Connect the white wire to the negative (-) terminal on the optional mini-relay.
4. Connect a red 18 gauge wire to the Normally Open (NO) post on the mini-relay.
5. Connect a red 18 gauge wire to the Common (C) post on the mini-relay.
6. Install the optional DRW into the door frame following the included instructions.
7. Connect the one of the red wires from the mini-relay to one of the red wires from the DRW.
8. Connect the other red wire from the mini-relay to the Yellow wire on the RT35 or either of the wires on the RT11.
9. Connect the remaining red wire on the DRW to the Yellow/Red wire on the RT35 or the remaining wire on the RT11
Chime Activated CO Rough In
1. Route a blue and a black 18 gauge wire from the Door Station location to the optional device the Chime Activated CO is to trigger. Following
this color convention will assist in the final installation of the Door Station.
2. Complete the installation as provide by the optional device being triggered.
Door Strike
Door Strike Power Supply
110V
N.O.
N.C.
COM
Door Strike Wire Relay for Lock Release
Relay
Door
Station
Location
+
_
Normally Closed
DRW
Normally Open
Common
VMC Wire Relay.ai
Figure 9