background image

HSLG OPERATOR INSTALLATION GUIDE

- 26 -

MODEL 

HSLG

 MECHANICAL PARTS LIST

REF
NO. PART 

NO. 

DESCRIPTION

   

2110-240 

Intermediate Shaft Assembly

 10 

2100-765 

Pulley Shaft

 14 

2200-213 

Sprocket, 41-B-9,  5/8” bore

   9 

2200-309 

Double Pulley, 7”

 11   

2200-233 

Set Collar Set, 5/8”

 92 

2200-215 

Precision Bearing, 5/8”

 72 

2200-333 

Key, 3/16” x 1 1/2”

 71 

2100-1750 

Key, 3/16” x 1 1/4”

 12 

2100-547 

Brake Disc

   

2110-274 

Clutch Shaft Assembly

 30 

2100-1008 

Clutch Shaft

 28 

2200-294 

Sprocket, 41-A-36, 1” bore

 31 

2100-669 

Clutch Hub (pinned)

 78 

2100-1007 

Clutch Hub (keyed)

 79 

2100-564 

Clutch Facing

 32 

2200-306 

Clutch Spring

 33 

2400-061 

Hex Nut, 5/8”-18

 89 

2400-062 

Jam Nut, 5/8”-18

 81 

2400-187 

Thrust Washer, 1” x 1/8”

   

2400-088 

Roll Pin, 3/16” x 1 3/8”

 27 

2200-292 

Sprocket, 41-B-12, 5/8” bore

   

2200-215 

Precision Bearing, 5/8”

 11 

2200-233 

Set Collar, 5/8”

 70 

2400-238 

Key, 3/16” x 1 1/4”

 82 

2400-273 

Key, 3/16” x 1/4”

   

2110-236 

Output Shaft Assembly

 15 

2100-917 

Output Shaft, 1”

 20 

2220-022 

Sprocket, 41-A-24 with Bearing 

 93 

2200-119 

Bearing only for 41-A-24 Sprocket

 21 

2110-131 

Shifter Block with Pins

 25 

2200-274 

Pillow Block Bearing, 1”

 97 

2100-1737 

Pillow Block Retaining Plate

 37 

2200-014 

Set Collar, 1” x 3/8” LTB

 26 

2200-091 

Set Collar, 1” x 5/8” LTB

 73 

2400-201 

Key, 1/4” x 1 1/2”

 16 

2200-968 

Sprocket, 40-B-22, 1” bore

   

2400-026 

Spring Pin, 3/16” x 1”

   

 

(Predrilled for Pillow Block)

 18 

2110-700 

Idler Assembly

   6 

2520-173R 

Rotary Limit Box Assembly

  

2500-764 

Limit 

Switch

   

2100-057 

Standard Limit Shaft

  

2200-030 

Limit 

Nut

  

2100-261 

Detent 

Plate

   

2110-162 

Limit Box Enclosure with Cover

   

2100-756 

Limit Box Cover only

       

2200-029 

Flange Bearing, 1/2” ID

  

2200-193 

E-Ring, 

1/2”

  

2400-203 

Spring 

Washer, 

1/2”

   7 

2200-008 

Limit Drive Sprocket, 48-B-10, 1/2” bore

   

 

For Drives up to 30 feet wide:

   

2200-008

 

Limit Box Sprocket, 48-B-10, 1/2” bore

   

2200-654 

#48 Chain, per foot, 27 Links required

   

 

For Drives from 31 to 45 feet wide:

   

2200-041 

Limit Box Sprocket, 48-B-15, 1/2” bore

   

2200-654 

#48 Chain, per foot, 29 Links required

   

 

For Drives over 45 feet wide:

   

2200-276 

Limit Box Sprocket, 48-B-20, 1/2” bore

   

2200-654 

#48 Chain, per foot, 30 Links required

 34 

2200-202 

#40 Chain, per foot

 36 

2400-038 

U-Bolt, 4 5/8”

     

 

2510-064 Three-Button Station with Lead 

Wires

102 

2100-1756 

Control Box Mounting Plate

 103 

2100-1781 

Accessory Shelf for Single Phase

  

 

Models 

only

REF
NO. PART 

NO. 

DESCRIPTION

   

 

Motors

 95 

2500-2307 

1/2 HP, 115V, 1 Phase

   

2500-2308 

1/2 HP, 208/230V, 1 Phase

   

2500-2309 

3/4 HP, 115V, 1 Phase

   

2500-2310 

3/4 HP, 208/230V, 1 Phase

   

2500-2311 

1 HP, 115V, 1 Phase

   

2500-2312 

1 HP, 208/230V, 1 Phase

   

2500-2313 

1/2 HP, 208/230/460V, 3 Phase

   

2500-2314 

3/4 HP, 208/230/460V, 3 Phase

   

2500-2315 

1 HP, 208/230/460V, 3 Phase

   

 

Capacitors

 

 

2500-2336 

Capacitor for 2500-2307 Motor

   

2500-2337 

Capacitor for 2500-2308 Motor

   

2500-1926 

Capacitor #1 for 2500-2309 Motor

   

2500-1930 

Capacitor #2 for 2500-2309 Motor

   

2500-1931 

Capacitor for 2500-2310 Motor

   

2500-2338 

Capacitor for 2500-2311 Motor

   

2500-1932 

Capacitor for 2500-2312 Motor

   

Magnetic Brakes (includes 41, 42, 44, 45 and 46)

 40 

2510-398 

115V

  

2510-399 

230V

  

2510-400 

460V

 41 

2220-983 

Brake and Puck Assembly

 42 

2500-177 

Brake Solenoid, 230 VAC

   

2500-178 

Brake Solenoid, 115 VAC

   

2500-1351 

Brake Solenoid, 460 VAC

 44 

2200-243 

Brake Spring (short)

 46 

2100-548 

Brake Rod

 45 

2100-541 

Brake Plate

 13 

2100-2091 

Bracket for Brake

   1 

2120-359-BT 

Enclosure Assembly Complete with Door

   

2120-360-BT 

Door Assembly only

   

2300-716 

Stop/Reset Button Cover

   

2110-643 

Lock Assembly with Keys

  

2200-540 

Replacement 

Key 

 53 

2110-234 

Rail Assembly

   3 

2100-573 

Spacer Plate

 94 

2200-207 

Double Pulley, 2”

 29 

2400-149 

Chain, #41, 30 Links

 22 

2120-132 

Shifter Lever

 23 

2100-910 

Locking Disconnect Lever

 24 

2200-291 

Disconnect Spring

 19 

2100-657-BT 

Rain Cover

 75 

2400-088 

Roll Pin

 87 

2100-2007 

Gate Bracket

 88 

2400-170 

U-Bolt, 3”

 84 

2100-258 

Chain Tension Bolt, 1/2”

 85 

2200-306 

Clutch/Chain Tension Spring

 86 

2400-090 

Hex Nut, 1/2”-13 (4)

  

2400-045 

Flat 

Washer, 

1/2”

  

2500-867 

Alarm, 

24VAC

    5 

2200-234 

V-Belt, 28”

  

2100-553 

Bearing 

Spacer

 90 

2200-150 

#41 Chain, per foot (20 links required)

 76 

2200-027 

#41 Master Link

   

2100-656-BT 

Side Plate, 1/2”

   

2100-059-BT 

Side Plate, 3/16”

 96 

2200-006 

#40 Master Link

   8 

2200-654 

#48 Chain, per foot (27 links required)

 77 

2200-010 

#48 Master Link

   91 

2400-422 

5/16-18 U-Nut (4)

 100 

2510-248 

Stop/Reset Button and Bracket Assembly

   

2100-1760 

Stop/Reset Button Mounting Bracket

  

2500-1495 

Stop/Reset 

Button

101 

2510-251-D 

Power On/Off Disconnect Assembly

   

 

with Receptacles (115V Models only)

   

2500-1956 

115VAC Duplex Receptacles only

   

2500-1957 

115VAC Switch only

   

2510-252-D 

Power On/Off Disconnect Assembly

   

 

for 230VAC Models

   

2500-2205 

230VAC Switch only

101 

2510-294 

Power On/Off Disconnect Assembly

   

 

for 3 Phase Operators

   

2500-034 

Power Switch only

Содержание HSLG

Страница 1: ...325 COMPLIANCE REQUIRES THE USE OF CONTACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMATIC OR REMOTELY CONTROLLED GATE OPERATORS USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 46...

Страница 2: ...board L E D Indicator Descriptions 12 Important Notes for Installation of Master Slave Applications 13 Surge Protector Instructions 13 Control and Accessory Connection Illustrations 14 17 ILLUSTRATION...

Страница 3: ...ate does not seem to operate properly it may affect the operator performance or greatly shorten the life of the unit The gate should be designed so that airflow through the fabric is ample to prevent...

Страница 4: ...e 9 for details of this connection as well as dip switch selection Note The SHIELD wire should be connected in both the master and slave operators MODEL HSLG SINGLE PHASE g n i r i W r e w o P s t l o...

Страница 5: ...tes which should be mounted on the outside top and bottom of the cabinet two 3 16 side plates which go on the top inside and two 1 2 side plates which should be mounted on the inside top of the cabine...

Страница 6: ...dler over the drive sprocket and then under the last idler Make sure you feed most of the chain through the sprockets for attaching to the back end of the gate Assemble the other gate bracket on the r...

Страница 7: ...and must be adjusted during installation Adjust the torque limiter tight enough to keep it from slipping during normal operation To adjust the torque limiter in model HSLG 1 Loosen the jam nut 2 To i...

Страница 8: ...perator after the limit switch is tripped Once the gate is in this position adjust the open limit nut until it activates the limit switch for open LSO 1 Press down on the detent plate and rotate the n...

Страница 9: ...nection Block This terminal block is used in conjunction with two operators to configure two gates to open and close together Dip Switches 1 This switch turns the auto close timer off on 2 This switch...

Страница 10: ...in prior to reaching a limit the gate will stop again and this time will sound the emergency alarm and lock out 4 51 CLOSE This function works exactly like the OPEN OBSTRUCTION except that it will onl...

Страница 11: ...tentiometer higher by 1 1 2 turns for all 115 Volt AC and 24 Volt DC operators and by 3 4 of a turn higher for all 230 Volt AC operators Additional fine adjustment by 1 4 turns may be necessary to eli...

Страница 12: ...or wired to the safety loop terminals SHADOW LOOP This indicator is lit when a shadow hold open signal is present This signal is generated by a loop detector wired to the shadow loop terminals This in...

Страница 13: ...d Lock Release Three Second Pre Start Warning Right Left Hand Selections SURGE PROTECTOR INSTRUCTIONS The optional surge protector should be connected to any inputs that have an accessory connected to...

Страница 14: ...HSLG OPERATOR INSTALLATION GUIDE 14 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 15: ...HSLG OPERATOR INSTALLATION GUIDE 15 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 16: ...HSLG OPERATOR INSTALLATION GUIDE 16 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 17: ...HSLG OPERATOR INSTALLATION GUIDE 17 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Страница 18: ...HSLG OPERATOR INSTALLATION GUIDE 18 LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 17 for details...

Страница 19: ...HSLG OPERATOR INSTALLATION GUIDE 19 EDGE LAYOUT ILLUSTRATION 1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Страница 20: ...HSLG OPERATOR INSTALLATION GUIDE 20 EDGE LAYOUT ILLUSTRATION 2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Страница 21: ...HSLG OPERATOR INSTALLATION GUIDE 21 PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 16 for details...

Страница 22: ...HSLG OPERATOR INSTALLATION GUIDE 22 PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 14 17 for additional details...

Страница 23: ...HSLG OPERATOR INSTALLATION GUIDE 23 TRACK GATE ILLUSTRATION...

Страница 24: ...pen or closed but no visible obstruction A The control board may have received a false obstruction input triggered by current sensing set too low Make sure the gate moves freely through its entire tra...

Страница 25: ...HSLG OPERATOR INSTALLATION GUIDE 25 MODEL HSLG MECHANICAL PARTS EXPLODED VIEW...

Страница 26: ...lf for Single Phase Models only REF NO PART NO DESCRIPTION Motors 95 2500 2307 1 2 HP 115V 1 Phase 2500 2308 1 2 HP 208 230V 1 Phase 2500 2309 3 4 HP 115V 1 Phase 2500 2310 3 4 HP 208 230V 1 Phase 250...

Страница 27: ...10 2510 249 Input Wire Harness Assembly 11 2510 250 Output Wire Harness Assembly 12 2510 261 Control Box Motor Harness Assembly 13 2500 071 Terminal Strip 16 141 14 2500 212 Transformer 115 24VAC 40VA...

Страница 28: ...Control Board only 10 2500 1980 3 Phase Motor Board 11 2500 1966 2 Amp Fuse for Control Board 12 2500 1975 3 Amp Fuse for Control Board 13 2510 253 Limit Switch Harness REF NO PART NO DESCRIPTION 14 2...

Страница 29: ...ace as necessary Check for proper tension and adjust if required Check all pulley setscrews for tightness and tighten if necessary 3 For operators with internal chain drives inspect chain and sprocket...

Страница 30: ...that these signs must remain at all times 8 Controls intended for user activation are located at least six feet 6 away from any mov ing part of the gate and where the user is prevented from reaching...

Отзывы: