LTC6804-1/LTC6804-2
50
680412fc
For more information
operaTion
Table 35. Command Bit Descriptions
NAME
DESCRIPTION
VALUES
MD[1:0]
ADC Mode
MD
ADCOPT(CFGR0[0]) = 0
ADCOPT (CFGR0[0]) = 1
01
27kHz Mode (Fast)
14kHz Mode
10
7kHz Mode (Normal)
3kHz Mode
11
26Hz Mode (Filtered)
2kHz Mode
DCP
Discharge Permitted
DCP
0
Discharge Not Permitted
1
Discharge Permitted
CH[2:0]
Cell Selection for ADC Conversion
Total Conversion Time in the 6 ADC Modes
CH
27kHz
14kHz
7kHz
3kHz
2kHz
26Hz
000
All Cells
1.1ms
1.3ms
2.3ms
3.0ms
4.4ms
201ms
001
Cell 1 and Cell 7
201µs
230µs
405µs
501µs
754µs
34ms
010
Cell 2 and Cell 8
011
Cell 3 and Cell 9
100
Cell 4 and Cell 10
101
Cell 5 and Cell 11
110
Cell 6 and Cell 12
PUP
Pull-Up/Pull-Down Current for
Open-Wire Conversions
PUP
0
Pull-Down Current
1
Pull-Up Current
ST[1:0]
Self-Test Mode Selection
Self-Test Conversion Result
ST
27kHz
14kHz
7kHz
3kHz
2kHz
26Hz
01
Self Test 1
0x9565
0x9553
0x9555
0x9555
0x9555
0x9555
10
Self test 2
0x6A9A
0x6AAC
0x6AAA
0x6AAA
0x6AAA
0x6AAA
CHG[2:0]
GPIO Selection for ADC Conversion
Total Conversion Time in the 6 ADC Modes
CHG
27kHz
14kHz
7kHz
3kHz
2kHz
26Hz
000
GPIO 1-5, 2nd Ref
1.1ms
1.3ms
2.3ms
3.0ms
4.4ms
201ms
001
GPIO 1
201µs
230µs
405µs
501µs
754µs
34ms
010
GPIO 2
011
GPIO 3
100
GPIO 4
101
GPIO 5
110
2nd Reference
CHST[2:0]* Status Group Selection
Total Conversion Time in the 6 ADC Modes
CHST
27kHz
14kHz
7kHz
3kHz
2kHz
26Hz
000
SOC, ITMP, VA, VD
748µs
865µs
1.6ms
2.0ms
3.0ms
134ms
001
SOC
201µs
230µs
405µs
501µs
754µs
34ms
010
ITMP
011
VA
100
VD**
*Note: Valid options for CHST in ADSTAT command are 0-4. If CHST is set to 5/6 in ADSTAT command, the LTC6804 treats it like ADAX command with
CHG = 5/6.
**The use of the ADSTAT command with CHST = 100 is not recommended unless special care is taken. See the Data Acquisition System Diagnostics
section for more details.