background image

19

Model MGT Gate Edge Transmitter Setup

Linear’s Model MGT Gate Edge Transmitter can be used with the RE-2 
for obstacle detection. When the gate edge sensor triggers the MGT 
transmitter, the RE-2 can be programmed to activate Relay #2 which would 
in turn, activate the obstacle input of the gate operator.

Press: 

 

 

 Obstacle 

 Facility 

 ID 

 

Obstacle:  0 = No MGT obstacle transmitter (default)

 

  1 = MGT obstacle transmitter used

 

Facility:  Facility code 0-15 of MGT transmitter

 

ID  = 5-digit ID number of transmitter

 

NOTE:

 The Facility and ID entries are not required if Obstacle is set to 

“0”.

Remote Keypad Address 

Default: 3

If a Linear Model AM-KP is used as a remote keypad the ADDRESS switch 
in the remote keypad needs to match the “address” setting in the RE-2. For 
most installations, simply set the remote keypad’s ADDRESS switch to “3” 
to match the RE-2 default setting. If required, use the following programming 
PPN to change the address number.

Press: 

 

 

 Address 

 

Address:  0 = Remote keypad disabled

 

  1-6 = Keypad address 1-6

 

NOTE:

 After changing the keypad address, restart the system using the 

RESTART button.

Sense Input Alternate Function 

Defaults:

 

SENSE #1 = SENSE

 

SENSE #2 = SENSE

Each of the two SENSE inputs can be independently programmed to act 
as INHIBIT inputs. As an INHIBIT input, as long as the input is grounded, 
access can not be granted for that input’s relay (1 or 2). A typical application 
would be connection of an external timer or service switch to temporarily 
prevent visitors from activating the access device.

Press: 

 

 

 Input 

 Type 

 

Input:  1 = SENSE #1

 

  2 = SENSE #2

 

Type:  0 = Input will perform as SENSE

 

  1 = Input will perform as INHIBIT

Keypad Lockout Count 

Default: 5 Tries

The Keypad Lockout Count sets the number of incorrect code entry attempts 
required to place the keypad in “lockout” for a one minute period. During 
“lockout” the keypad will not accept any code entries. The Keypad Lockout 
Count effects both the main and remote keypads.

Press: 

 

 

 Count 

 

Count  = 2-7 Incorrect entries

Anti-passback Time 

Default: Off

The Anti-passback feature prevents the same entry code or transmitter 
from being used to gain access more than once during the set time.

Press: 

 

 

 Time 

 

Time:  0 = No anti-passback

 

  1-4 = Anti-passback time (in minutes)

Modem Ring Detect On/Off 

Default: On

The RE-2’s built-in modem monitors the telephone line for telephone rings. 
When the Modem Ring Detect is enabled, the modem will answer the 
telephone if two consecutive telephone calls occur within 30 seconds. The 
Modem Ring Detect can be disabled, this will also disable any computer 
based programming of the RE-2.

Press: 

 

 

 Detect 

 

Detect:  0 = Ring detect OFF

 

  1 = Ring detect ON

Keypad Beeps On/Off 

Default: On

The default setting causes the main keypad to beep when each key is 
pressed. The beeps can be disabled.

Press: 

 

 

 Keypad Beeps 

  Keypad Beeps:  0 = Beeps OFF
 

  1 = Beeps ON

Relay #1 Tone On/Off 

Default: Off

The default setting does not cause the annunciator to sound when Relay #1 
is activated. The Relay #1 activation tone can be enabled.

Press: 

 

 

 Relay #1 Tone 

  Relay #1 Tone:  0 = Tone OFF
 

  1 = Tone ON

Relay #2 Tone On/Off 

Default: Off

The default setting does not cause the annunciator to sound when Relay #2 
is activated. The Relay #2 activation tone can be enabled.

Press: 

 

 

 Relay #2 Tone 

  Relay #2 Tone:  0 = Tone OFF
 

  1 = Tone ON

Relay Tone Duration 

Default: 1 Second

The default setting causes the annunciator to sound for 1 second when 
Relay #1 or Relay #2 is activated (if the tones are enabled). The length of 
the activation annunciation can be changed.

Press: 

 

 

 Tone Length 

Tone Length = Tone length in Seconds 1-15

Voice Synthesizer On/Off 

Default: On

When the voice synthesizer is on the RE-2 will sound voice prompts during 
operation and programming. If the voice synthesizer is off, the system will 
sound beeps to indicate conditions. The HELP button will announce “

Enter 

code or press call button to contact resident

” regardless of this setting.

The beeps produced when the voice synthesizer is off are:

•  1 Short beep — Keypad key pressed

•  2 Short beeps — Programming entry was valid

•  1 Long beep — Programming entry was invalid

Press: 

 

 

 Voice 

 

Voice:  0 = Voice synthesizer OFF

 

  1 = Voice synthesizer ON

Automatic Daylight Savings Time Clock Adjustment On/Off  Default: On

The RE-2’s internal clock used for controlling system functions and time 
stamping of the event log automatically adjusts for daylight savings time. 
For areas where daylight savings time is not observed, this feature may 
be disabled.

Press: 

 

 

 Daylight Savings 

 Daylight Savings: 0 = Daylight Savings Adjust OFF
 

  1 = Daylight Savings Adjust ON

Automatic Door/Gate Open Time 

Default: Not Set

Each control relay can be programmed for automatic activation. One or two 
Time Zones can be assigned to a relay. The relay will activate and remain 
latched during the active period of the Time Zone.

Press: 

 

 

 Relay 

 1st Time Zone 

 2nd Time Zone 

 

Relay:  1 = Relay #1

 

  2 = Relay #2

  1st Time Zone  = Time Zone 1-7
  2nd Time Zone  = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)

Содержание RE-2

Страница 1: ...dential Telephone Entry System With Built in Wireless Receiver 760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation Programming and Operation Instructions ...

Страница 2: ...R PROOF TAMPER RESISTANT HOUSING SUPERHETERODYNE RADIO RECEIVER REMOTE KEYPAD SUPPORT BRIGHT WHITE LED DOWNLIGHT 2 HEAVY DUTY FORM C N O N C RELAY OUTPUTS TIMED ANTI PASSBACK KEYPAD LOCKOUT TACTILE KEY FEEL TWO DOOR SENSE INHIBIT INPUTS TWO OPEN REQUEST INPUTS ACCESS KEYSWITCH PROVISION REMOVABLE TERMINAL BLOCKS OPTIONAL COLOR CCTV CAMERA PRODUCT DESCRIPTION 1 INSTALLATION INFORMATION 2 COMPONENT ...

Страница 3: ...access through the RE 2 s built in radio receiver Each transmitter can be individually suspended or re activated One facility code can be programmed to identify each block of transmitters Programming of individual non block coded transmitters is limited to 24 transmitters by entering one transmitter per block System Features Time Zones The RE 2 contains an internal clock and calendar Seven program...

Страница 4: ... inside a dedicated conduit that is at least six inches away from any AC line wiring Power Supply Use the supplied 16 volt 20 VA transformer to power the RE 2 DO NOT POWER ANY OTHER EQUIPMENT FROM THE SAME TRANSFORMER use a separate power supply Keep the system power wires as short as practical to reduce the chance of noise and hum pickup For low voltage power wire runs up to 100 feet use 18 AWG T...

Страница 5: ... entry system s speakerphone 1 HELP BUTTON Pressing this button causes the system to play the help message to instruct the visitor on system use 2 CALL BUTTON Pressing this button causes the system to call the residence telephones with a distinctive ring signal 3 OPTIONAL COLOR CCTV CAMERA Location for the optional Model CCM 2 color CCTV camera The camera views the keypad area 4 ANTENNA CONNECTOR ...

Страница 6: ...CTRIC DOOR STRIKE MAGNETIC DOOR LOCK ACCESS DEVICE POWER SUPPLY NOTE A MAGNETIC LOCK AND DOOR STRIKE ARE BOTH SHOWN TYPICALLY ONLY ONE IS USED 16 VAC 20 VA TRANSFORMER TELCO OPEN 1 KEYPAD GND KEYPAD DAT 1 KEYPAD DAT 0 KEYPAD PWR TRANSFORMER TRANSFORMER BATTERY NEG BATTERY POS SENSE 1 COMMON KEYPAD CLK KEYPAD DVAL OPEN 2 RELAY 1 RE 2 TELEPHONE ENTRY SYSTEM SENSE 2 N O COM N C N O COM N C RELAY 2 RI...

Страница 7: ... mounting location 3 Install any additional mounting material required to provide surfaces inside the wall for attaching the trim ring 4 Place the trim ring in the wall hole Check for level then attach the trim ring with screws into the side tabs 5 Drill the cabinet s four self drill mounting holes the appropriate size for the hardware 6 Attach the cabinet to the trim ring using self tapping screw...

Страница 8: ...PHONE WIRING OPTIONS Shared Line This is the standard configuration The telephone line is routed through the RE 2 to the house phones Pressing the Call button on the RE 2 will cause the RE 2 to disconnect the house phones from the telephone company line and generate a ring signal that is heard on the house phones Dedicated Line Pressing the Call button on the RE 2 will cause the RE 2 to sieze the ...

Страница 9: ...cond RE 2 Simultaneous visitors at multiple units used on a single line wired in the Ring Down Mode will cause a conference call effect between units Figure 10 Multiple Unit Wiring TIP RING TIP RING TIP RING TIP RING TELCO RE 2 TELCO RE 2 HOUSE HOUSE TELEPHONE BYPASS MODULE EARTH GROUND GROUND STAKE FIRST RE 2 ENTRY SYSTEM TELCO RING TIP RING TIP EARTH HOUSE CASE GROUND LAST RE 2 ENTRY SYSTEM TELC...

Страница 10: ...h wiring and installation 6 To use the door sense feature to detect forced entry or door ajar conditions install a normally closed door switch on the door or pedestrian gate and route two wires from the switch to the RE 2 Connect the door sense switch to the RE 2 SENSE 1 and COMMON terminals See programming PPN 24 27 to define when Relay 2 will activate based on the sense input Figure 12 Gate Inst...

Страница 11: ...phone Bypass Module EARTH GROUND terminal to the earth ground wire 3 Connect the RE 2 EARTH terminal to one of the case ground studs this connection is mandatory for lightning protection Case Ground A ground wire connects the front and rear cases together Be sure to re connect this wire before completing the installation Refer to Figure 15 for case ground wire attachment details OPTIONAL REMOTE AN...

Страница 12: ...nted as shown see Figure 21 Secure the keyswitch with the large switch nut 3 Plug the two keyswitch snap on wire leads supplied with the switch onto the keyswitch COM and N O pins see Figure 22 4 Connect one keyswitch wire to the RE 2 OPEN 1 terminal Connect the other keyswitch wire to the RE 2 COMMON terminal see Figure 23 SET SWITCH TO NUMBER 3 Figure 18 Setting the Keypad Device Address OPEN 1 ...

Страница 13: ...hole in the camera bracket towards the edge of the RE 2 case Secure the camera with the two retaining brackets and screws see Figure 25 5 Replace the RE 2 circuit board Secure the board with the six screws 6 Connect the camera s 4 conductor cable to the RE 2 s CAMERA connector see Figure 26 7 Connect the video cable to the RE 2 s VIDEO OUT connector see Figure 26 8 Connect the other end of the vid...

Страница 14: ...to the desktop for easy future access 4 Enter the RE 2 s programming master password 123456 unless changed into the Password area Select Save Password if you want the computer to retain the password 5 Select Connect and wait for the modem to connect to the RE 2 6 Switch to the browser software and enter into the address line http 192 168 20 10 re1 html save this address as a favorite or bookmark s...

Страница 15: ...ENTER 192 168 20 11 THEN CLICK ADVANCED 14 UN CHECK USE DEFAULT GATEWAY ON REMOTE NETWORK AND UN CHECK USE IP HEADER COMPRESSION THEN CLICK OK SETTING UP A WINDOWS XP DIAL UP NETWORK CONNECTION BE SURE ONLY THESE FIRST TWO BOXES ARE CHECKED 5 NEW CONNECTION WIZARD INTERNET CONNECTION SELECT CONNECT USING DIAL UP MODEM 6 NEW CONNECTION WIZARD CONNECTION NAME ENTER RE 2 LOCAL FOR A LOCAL CONNECTION ...

Страница 16: ...te Telephone Connection 1 Dial the telephone number of the line that the RE 2 is connected to 2 Let the telephone ring twice and hang up 3 After 10 seconds but before 30 seconds call back to the same telephone number 4 The RE 2 will answer and sound a tone for 2 seconds 5 The RE 2 will wait for approximately six seconds for the caller to enter the Master Programming Code 6 Enter password 123456 un...

Страница 17: ...7 ERASING ALL ENTRY CODES PPN 97 PAGE 16 CHANGING THE MASTER CODE PPN 98 PAGE 16 RESET SYSTEM DEFAULTS PPN 200 PAGE 18 FACTORY DEFAULTS PPN 1 ENTRY CODE LENGTH 4 DIGITS PPN 8 TRANSMITTER LEFT OR TOP LEFT BUTTON ACTIVATES RELAY 1 TRANSMITTER RIGHT OR TOP RIGHT BUTTON ACTIVATES RELAY 2 TRANSMITTER TOP BUTTON ACTIVATES RELAYS 1 AND 2 TRANSMITTER LOWER LEFT BUTTON ACTIVATES NONE TRANSMITTER LOWER RIGH...

Страница 18: ...s the number of digits for all the entry codes programmed Press Length Length 2 6 for entry code length NOTE If the Entry Code Length is going to be changed from the factory default of four digits make this change first before programming any entry codes Adding a New Entry Code Use this PPN to add up to 100 entry codes Press Code Code Relay Time Zone Code The new entry code 1 999999 depending on c...

Страница 19: ...st ten seconds of time allowed Press Limit Limit 15 255 Seconds allowed Call Waiting Feature On Off Default On Turns the call waiting feature on or off If call waiting is on factory default and the resident is on the telephone at the same time a visitor calls the RE 2 will generate beeps on the resident s telephone line to signal that a visitor is calling The resident has the option to switch to t...

Страница 20: ...mming and Command Prefixes Defaults Programming Command The resident command prefix is entered on a local telephone prior to entering a command number to control one of the relays or open voice communications with the RE 2 The resident programming prefix is entered on a local telephone or the main keypad prior to programming the RE 2 Press Programming Command Programming 0 1 2 3 Command 0 1 2 3 AD...

Страница 21: ... the modem will answer the telephone if two consecutive telephone calls occur within 30 seconds The Modem Ring Detect can be disabled this will also disable any computer based programming of the RE 2 Press Detect Detect 0 Ring detect OFF 1 Ring detect ON Keypad Beeps On Off Default On The default setting causes the main keypad to beep when each key is pressed The beeps can be disabled Press Keypad...

Страница 22: ... CALL button to call the residence 2 Have the resident talk at a normal volume level while adjusting the SPEAKERPHONE VOLUME control Adjusting the control clockwise increases the volume counterclockwise decreases the volume Digital Speech Volume The DIGITAL SPEECH VOLUME adjustment controls the audio level of the voice synthesizer This adjustment effects the audio level of the voice synthesizer fr...

Страница 23: ...g feature is enabled the system will forward the visitor s call to an outside telephone number during the programmed time for call forwarding The resident can control access from the forwarded telephone number The system can be programmed to produce a Do Not Disturb message for the visitor during times when privacy is desired No call will be generated to the residence and access will be denied Pre...

Страница 24: ...Facility ID Action Facility Facility code 1 16 of transmitter 0 no facility code ID 5 digit ID number of transmitter Action 0 Suspend transmitter 1 Re activate transmitter Maximum Number of Visitor Rings Press Rings Rings 1 15 Rings maximum Visitor Talk Time Limit Press Limit Limit 15 255 Seconds allowed Call Waiting Feature On Off Press Call Waiting Call Waiting 1 ON 2 OFF Call Forwarding Press F...

Страница 25: ...ct line ring and tip to house ring and tip Check line for buzz with test set 2 Disconnect 16 VAC wires from terminal strip if buzz goes away one side of the transformer wires is grounded 3 Check all connections for any shorts to ground Telephones in residence will not ring 1 Verify that the Do Not Disturb feature is not on while testing 2 Verify that the Call Forwarding feature is not forwarding t...

Страница 26: ...H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O ...

Страница 27: ... 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __...

Страница 28: ... power and therefore limited range A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings Changes or modifications to the device may void FCC compliance Infrequently used radio links should be tested regularly to protect against undetected interference or fault A gener...

Отзывы: