background image

1

COMPONENT LOCATIONS

WIRING DIAGRAM

218370 C     IMAGE 3

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
"LOCKOUT"
INDICATOR

KEYPAD

SOLID STATE
WHITE LED
DOWN LIGHT

MASTER CODE
RESET JUMPER
(JP2)

TERMINAL
BLOCK #1
(TB1)

TERMINAL
BLOCK #2
(TB2)

BEEPER
LEVEL
JUMPER (JP1)

FACEPLATE

BEZEL

MOUNTING
PLATE

1 - AC OR DC

2 - AC OR DC

3 - N.O.

4 - COM

5 - N.C.

6 - N.O.

7 - COM

8 - N.C.

SENSE - 8

COM - 7

REQUEST-TO-EXIT - 6

EARTH GROUND - 5

OUTPUT #3 COM - 4

OUTPUT #3 - 3

OUTPUT #4 - 2

OUTPUT #4 COM - 1

12-24 VOLT

AC OR DC

POWER

MAIN RELAY

5 AMPS @

28 VDC MAX.

AUXILIARY

RELAY 1 AMP

@ 28 VDC MAX.

TERMINAL

BLOCK 2

TERMINAL

BLOCK 1

AK-2 TERMINALS

CAUTION

IF THE UNIT IS AC POWERED,

MAKE SURE THE SECONDARY OF THE

SYSTEM TRANSFORMER IS ISOLATED

FROM EARTH GROUND

OPTIONAL WIRING

REQUIRED WIRING

OTHER WIRING

NOTES: 
1. ALARM SHUNT SET FOR AUXILIARY RELAY
2. TERMINAL BLOCK #2, TERMINAL 8 SET FOR DOOR SENSE

GROUND

STAKE

N.C. DOOR

SWITCH

ALARM

CONTACT

TO ALARM

SYSTEM

POWER
SUPPLY

ELECTRIC

DOOR

STRIKE

AUXILIARY

OUTPUTS

100 mA MAX.
TO COMMON

REQUEST

TO EXIT

BUTTON

TYPICAL DOOR INSTALLATION WIRING

Figure 1. Component Locations

Figure 2. Wiring Diagram

Содержание AK-2

Страница 1: ...7 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 218370 C IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AK 2 LINEAR P N 218370 C INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE 1...

Страница 2: ...be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power An internal jumper is provided to reset the master code The...

Страница 3: ...1 12 24 VOLT AC OR DC POWER MAIN RELAY 5 AMPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 2 TERMINAL BLOCK 1 AK 2 TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF...

Страница 4: ...e or access device Install the electrical box in the wall Screw the mounting plate onto the electrical box see Figure 5 Final Keypad Installation After wiring the keypad see next page complete the ins...

Страница 5: ...route two wires from the switch to the keypad box Connect the door switch to the keypad s SENSE terminal TB1 8 and COM terminal TB1 7 If an inhibit switch or timer is going to be used for temporarily...

Страница 6: ...1 Code Code Relay Code The new entry code 1 999999 depending on code length Relay Relay output entry code will activate 1 Main Relay 2 Auxiliary Relay 3 Both Relays The yellow indicator will flash qui...

Страница 7: ...ts which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxili...

Страница 8: ...C Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 100 mA 24 VDC max...

Отзывы: