Linear Access AK-2 Скачать руководство пользователя страница 7

5

Program all normal entry codes to use the Main Relay (Relay #1), 
and only Relay #1 as the output relay. Program the code(s) that 
you want to use to hold the output for an indefi nite period to the 
Auxiliary Relay (Relay #2). See the following example that sets 
entry codes 1234 for normal and 5678 for toggle operation.

Press:

  

0 1 #

 

1 2

 

3 4

 

# 1 2

 

3 4

 

# 1

 

#

01 = Programming Step; 1234 = Entry Code; 1 = Main Relay

Press:

  

0 1 #

 

5 6 7 8

 

# 5 6 7

 

8

 

# 2

 

#

01 = Programming Step; 5678 = Entry Code; 2 = Auxiliary Relay

Typical Toggle  Mode Wiring

For devices triggered by a normally open circuit, wire the contacts 
of the Main and Auxiliary Relays in parallel (see the Figure below). 
Either relay will be able to trigger the access device. Entry codes 
programmed for the Auxiliary Relay will be able to hold the output 
on.

Select Door Sense or Inhibit Input 

Default: Door Sense

The input on Terminal Block TB1, Terminal #8 can be programmed for 

DOOR 

SENSE

 or 

INHIBIT

.

Press:

  

1 0 #

 

Input 

#

Input

 = 0 for Door Sense, = 1 for Inhibit

When programmed for 

DOOR SENSE

, if an open condition on the input occurs 

before access is granted (with an entry code or with the request-to-enter input) a 

FORCED ENTRY

 output will occur. If an open condition remains 60 seconds after 

a relay activation for access, a 

DOOR AJAR

 output will occur.

When programmed for 

INHIBIT

, a closed condition on the input will prevent 

Relay #1 from activating when access is requested with an entry code. This mode 
is typically used with an external timer to disable the access device at certain 
times.

Select Forced Entry Output 

Default: Output #3

Sets which output activates if the 

DOOR SENSE

 input opens before access is 

granted. This output is not timed.

Press:

  

1 1 #

 

Output

 

#

Output

 = Output to Activate (0-4)

1 = Main Relay  2 = Auxiliary Relay  3 = Output #3  4 = Output #4  0 = No Output

Select Door Ajar Output 

Default: Output #4

Sets which output activates if the 

DOOR SENSE

 input stays open 60 seconds 

after access is granted. This output is not timed.

Press:

  

1 2 #

 

Output

 

#

Output

 = Output to Activate (0-4)

1 = Main Relay,  2 = Auxiliary Relay,  3 = Output #3,  4 = Output #4,  0 = No Output

Select Keypad Lockout Output 

Default: No Output

Sets which output activates when the keypad is “locked out” after too many 
incorrect entry code attempts. The lockout time is 60 seconds.

Press:

  

1 3 #

 

Output

 

#

Output

 = Output to Activate (0-4)

1 = Main Relay,  2 = Auxiliary Relay,  3 = Output #3,  4 = Output #4,  0 = No Output

Select Keypad Active Output 

Default: No Output

Sets which output activates when any keys are pressed. This output is timed. If 
toggle mode is selected for the output, the timer value defaults to 2 seconds.

Press:

  

1 4 #

 

Output

 

#

Output

 = Output to Activate (0-4)

1 = Main Relay,  2 = Auxiliary Relay,  3 = Output #3,  4 = Output #4,  0 = No Output

Select Alarm Shunt Output 

Default: No Output

Sets which output activates during the time access is granted. (Use this output 
to shunt alarm contacts attached to the access door.) This output may be timed 
or toggled.

Press:

  

1 5 #

 

Output

 

#

Output

 = Output to Activate (0-4)

1 = Main Relay,  2 = Auxiliary Relay,  3 = Output #3,  4 = Output #4,  0 = No Output

Select Request-to-Exit Output 

Default: Main Relay

Sets which output activates when the Request-to-Exit input is grounded. This 
output may be timed or toggled.

Press:

  

1 6 #

 

Output

 

#

Output

 = Output to Activate (0-4)

1 = Main Relay,  2 = Auxiliary Relay,  3 = Output #3,  4 = Output #4,  0 = No Output

Main Relay On-time 

Default: 2 Seconds

Sets the length of time the Main Relay activates when triggered.

Press:

  

2 1 #

 

Seconds

 

#

Seconds

 = Output time in seconds (0-60), 99 = Toggle Mode

Auxiliary Relay On-time 

Default: 2 Seconds

Sets the length of time Auxiliary Relay activates when triggered.

Press:

  

2 2 #

 

Seconds

 

#

Seconds

 = Output time in seconds (0-60), 99 = Toggle Mode

Solid-state Output #3 On-time 

Default: 2 Seconds

Sets the length of time Output #3 activates when triggered.

Press:

  

2 3 #

 

Seconds

 

#

Seconds

 = Output time in seconds (0-60), 99 = Toggle Mode

Solid-state Output #4 On-time 

Default: 2 Seconds

Sets the length of time Output #4 activates when triggered.

Press:

  

2 4 #

 

Seconds

 

#

Seconds

 = Output time in seconds (0-60), 99 = Toggle Mode

Beep Sounds on Keystrokes 

Default: Yes

Selects whether or not the keypad beeps as each key is pressed.

Press:

  

4 0 #

 

Sound

 

#

Sound

 = 1 for Yes, = 0 for No

Beep Sounds During Main Relay 

Default: No

Selects whether or not the keypad beeps during Main Relay activation.

Press:

  

4 1 #

 

Sound

 

#

Sound

 = 1 for Yes, = 0 for No

218370 C     IMAGE 7

N.O.

COMMON

N.C.

N.O.

COMMON

N.C.

MAIN

RELAY

AUXILIARY

RELAY

AK-2

OUTPUTS

ACCESS

DEVICE

EITHER RELAY CAN TRIGGER
THE ACCESS DEVICE

Содержание AK-2

Страница 1: ...7 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 218370 C IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AK 2 LINEAR P N 218370 C INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE 1...

Страница 2: ...be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power An internal jumper is provided to reset the master code The...

Страница 3: ...1 12 24 VOLT AC OR DC POWER MAIN RELAY 5 AMPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 2 TERMINAL BLOCK 1 AK 2 TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF...

Страница 4: ...e or access device Install the electrical box in the wall Screw the mounting plate onto the electrical box see Figure 5 Final Keypad Installation After wiring the keypad see next page complete the ins...

Страница 5: ...route two wires from the switch to the keypad box Connect the door switch to the keypad s SENSE terminal TB1 8 and COM terminal TB1 7 If an inhibit switch or timer is going to be used for temporarily...

Страница 6: ...1 Code Code Relay Code The new entry code 1 999999 depending on code length Relay Relay output entry code will activate 1 Main Relay 2 Auxiliary Relay 3 Both Relays The yellow indicator will flash qui...

Страница 7: ...ts which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxili...

Страница 8: ...C Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 100 mA 24 VDC max...

Отзывы: