![Linea Link HS Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/linea/link-hs/link-hs_user-manual_1920990029.webp)
Linea CLHS Series Camera
Camera Operation
•
27
Flat Field Parameters
This
Flat Field
category contains a number of features that are used to correct image distortion
due to lens vignetting and uneven illumination.
Flat Field
Parameter
Description
Mode
Off – Flat field correction coefficients are not applied.
On – Flat field correction coefficients are applied.
Initialize – Sending this value will reset all current coefficients (offsets to
0 and gains to 1x).
Calibration Algorithm
Basic – Direct calculation of coefficients based on current average line
values and target.
Calibration Target
After calibration all pixels will be scaled to output this level.
Range depends on pixel format:
•
8-bit: 0 to 255 DN
•
12-bit: 0 to 4095 DN
Calibration Sample Size
Number of lines to average when calibrating.
Possible values: 2048 or 4096
ROI Offset X
Together with “ROI Width”, specifies the range of pixels to be calibrated.
Pixel coefficients outside this range are not changed. It is possible to
calibrate different regions sequentially.
ROI Width
Width of ROI, in pixels.
Calibration FPN
Save average line (of “Calibration Sample Size” rows). This is the first
user correction applied – it is subtracted from each line.
This feature may not be of use to many users as the camera already
subtracts true “dark current”, but it may be useful for some to provide a
per pixel offset correction.