Safety Instructions

  

IM3000 Flowmeter Safety Instructions

WARNING

Personal Safety;

 Through out this manual and on all safety signs, the precautionary statements 

(

“DANGER”

“WARNING”

“CAUTION”

 and 

“NOTICE”

) can be found, followed by a hazard description 

and preventative actions to be taken. These precautions are intended for the personal safety of the operator and 

those within the vicinity of the machinery. Please take time to read these precautions.

Hazard Severity Panels

Background 

Color of 

Panel

Contrast 

Color

Meaning/Use

Hazard Severity Panel Illustration

Red

White

Danger hazard severity panels indicate a high 

level of risk that can result in serious injury 

or death. The signal word “Danger” is to be 

limited to the most extreme situation. Danger 

panels are not to be used for property damage 

hazards unless personal injury risk appropriate 

to this level is also involved.

Orange

Black

Warning hazard severity panels indicate a 

moderate level of risk that if ignored, could 

result in death or serious injury. Warning pan-

els should not be used for property damage 

unless personal injury risk appropriate to this 

level is also involved.

Yellow

Black

Caution hazard severity panels indicate a low 

level of risk that if not avoided, minor or moder-

ate injury could result. Caution panels without 

the alert symbol may be used to alert against 

unsafe practices that can result in property 

damage only.

Blue

White

Notice severity panels are used to address 

practices not related to personal injury. The 

alert symbol is never used with Notice panels. 

As an alternative to the signal “Notice”, the 

word “Caution” without the alert symbol may 

be used to indicate a message not related to 

personal injury.

WARNING

Machine Safety:

 Additional precautionary statements (

“ATTENTION”

 and 

“IMPORTANT”

) are 

intended for machine safety and are followed by specific instructions.

ATTENTION

: The word 

“ATTENTION”

 is used to warn the operator of potential machine damage if a certain pro-

cedure is not followed.

IMPORTANT

: The word 

“IMPORTANT”

 is used to provide the reader with information necessary to prevent minor 

machine damage if a certain procedure is not followed.

Содержание GROWSMART IM3000

Страница 1: ...IM3000 Flow Meter Installation Manual P N 1605606 Rev A ECN 32937...

Страница 2: ......

Страница 3: ...gnored could result in death or serious injury Warning pan els should not be used for property damage unless personal injury risk appropriate to this level is also involved Yellow Black Caution hazard...

Страница 4: ...gns in legible condition Replace any missing or damaged safety signs Learn how to operate the machine and controls properly Do not allow anyone to operate the meter without proper instruc tions Keep t...

Страница 5: ...Lindsay Dealer using the proper lifting equipment may perform this task Use caution when lifting heavy objects Components weighing in excess of 50 lbs 22 7 kg must be lifted with the assistance of an...

Страница 6: ...f the containers Do not transport or operate batteries at temperatures beyond their specified range Do not crush break or disassemble the battery Do not short circuit recharge overcharge or connect th...

Страница 7: ...s Les panneaux d avertissement ne doivent pas tre utilis s pour signaler des risques de d g ts mat riels moins qu ils n impliquent aussi des risques de blessures physiques correspondant ce niveau Jaun...

Страница 8: ...e que les panneaux de s curit soient bien lisibles Remplacez tout panneau de s curit manquant ou ab m Apprenez utiliser la machine et les commandes correctement Ne laissez aucune personne utiliser le...

Страница 9: ...ment de levage appropri peut effectuer cette t che Faites attention lorsque vous soulevez des objets lourds Les composants pesant plus de 22 7 kg 50 livres doivent tre soulev s avec l assistance d un...

Страница 10: ...r des conteneurs Ne transportez pas de batteries ou ne les faites pas fonctionner des temp ratures qui ne sont pas comprises dans la plage indiqu e N crasez pas ne cassez pas ou ne d montez pas la bat...

Страница 11: ...oubleshooting The IM3000 comes in these models according to pipe diameter size IM3000 04 for 4 pipe IM3000 06 for 6 pipe IM3000 08 for 8 pipe IM3000 10 for 10 pipe IM3000 12 for 12 pipe Features The G...

Страница 12: ...cs housing is constructed from die cast aluminum with a powder coated exterior The flanges are ANSI 150 which provides a maximum pressure rating of 150 psi The IM3000 is rated for operating between 14...

Страница 13: ...t the electrodes enough to avoid air bubble and sediment locations that typically occur over center within the pipe The following diagram shows proper and im proper installation options Air bubbles ca...

Страница 14: ...be 10 times the pipe diameter at the meter inlet and three times the pipe diameter at the meter outlet In chemigation applications the IM3000 flowmeter must be placed either upstream from the chemica...

Страница 15: ...ter Dimensions Dimensions are in Inch mm Nom H H1 L D D1 t1 BC 4 100 14 30 363 9 80 249 10 24 260 3 15 80 9 00 227 0 94 24 7 50 191 6 150 16 00 406 10 50 267 12 28 312 5 12 130 11 00 279 1 00 25 9 50...

Страница 16: ...ion NOTE Make sure the ground wire or lug is between the flange bolt head or nut and the outside surface of the mating pipe flange This grounding must be completely isolated from the flowmeter See the...

Страница 17: ...ternal Power Black 7 External Power Wiring BOSS to the IM3000 Pink Supply to TB 3 5 Black Supply to TB 3 4 Purple Pulse to TB 3 4 Brown Pulse to TB 3 2 Resistor to TB3 2 and TB3 5 Bare drain wire can...

Страница 18: ...000 Pink Supply to TB 4 2 Black Supply to TB 4 1 Purple Pulse to TB 4 1 Brown Pulse to TB 4 3 Resistor to TB 4 2 and 4 5 Bare drain wire can be connected to panel ground IM3000 K Factors Pipe Size Raw...

Страница 19: ...s of life An external expansion battery pack can be used to double battery life This expansion pack consists of 4 additional 3 6V D sized lithium batteries that link to the meter body via IP68 cable c...

Страница 20: ...the center of the battery pack and remove the battery pack from the meter housing 8 Take the new battery pack and route the signal and excitation cable harnesses through the center of the battery pack...

Страница 21: ...e housing through the seal Outputs The IM3000 provides 5 output types 1 Total gallons x 1000 to a rate of Gallons per Minute GPM This is the default 2 Total Acre Inches to a rate of GPM 3 Total Acre F...

Страница 22: ...attery power a little battery icon displays in the top left corner of the screen The meter continuously monitors battery life When the battery power is low the following warning will display and the b...

Страница 23: ...P N 1605606 Rev A ECN 32937 13 IM3000 Installation Manual If direction of flow of the medium is reversed the meter will stop measuring and display the warning Empty Pipe G P M R a t e...

Страница 24: ...power source allows more flow averaging Rapidly changing conductivity for chemigation applications Install meter upstream of the chemi gation entry location or far enough downstream for thorough flui...

Страница 25: ...P N 1605606 IM3000 Installation Manual Revisions Revisions Date Revision ECN Published ECN Description 10 17 2014 A 32937 32937 New Release...

Страница 26: ...P N 1605606 IM3000 Installation Manual Revisions...

Отзывы: