P/N 1605606 Rev A (ECN 32937)
3
IM3000 Installation Manual
Meter Positioning
It is important to install flowmeters so the readings are always accurate. The meters are designed to give a zero
reading should one or more electrodes become exposed. Air bubbles and sediment in the pipe can cause false
readings.
For the best performance, install the flowmeter in pipeline locations where the pipe will be full when there is flow.
Also, rotating the pipe 45° (or one flange hole position) will offset the electrodes enough to avoid air bubble and
sediment locations that typically occur over center within the pipe. The following diagram shows proper and im-
proper installation options.
Air bubbles can
pass over electrode
Sediment can build up
on this electrode
Problematic Sensor Orientation
Recommended Sensor Orientation
Turned 45° the
electrodes remain
submerged
Turned 45° the
electrodes are
above sediment
buildup level
Problematic Meter Positioning
Problematic Meter Positioning
Recommended Meter Positioning
Recommended Meter Positioning
Air can be trapped,
loss of accuracy
Allows air to bleed off,
higher accuracy
Vertical downflow,
open discharge
Vertical upflow
with full pipe