background image

  

AC Power Director: 

1.

AC HFC power can be sent to remote locations via the output ports depending on the configuration of the 
power port jumpers.  

2.

Each RF output port has a plug-in AC Power Director/Jumper. 

3.

Check the system maps to determine which power directors should be inserted in a power passing 
position.  Install each power director as required.  Refer to Figure 5. 

General Set-up: 

1.

Test the optical input power on the system downstream cable with an optical power meter to verify 
that it is within the optical input range specification.  

2.

Clean the optical connectors on the node and on the service cable then connect them together, 
matching the system downstream cable to the node receiver and the system upstream cable to the 
laser transmitter. 

3.

Verify that the total upstream RF signal level (from all ports) is within the node’s specified input range, 
then connect the coaxial cable to the node’s RF In/Out F-port.    

4.

The LBON4000 must be grounded, Use a split-bolt grounding stud or your system preferred ground 
attachment to ground the Node housing to earth ground.  Install the split-bolt grounding stud on the 
base housing. Refer to Figure 6. 

 

• For a strand-mounted, install the grounding stud in the threaded hole on the base. 

 

• For a pedestal or surface mounted Node, remove one of the two strand mount brackets, 

 

  and install the grounding stud in the threaded hole. 

       Loosen the top nut and insert the grounding cable. (You may need to remove the nut to insert cable.     
       With the grounding cable installed, tighten the top nut to secure the cable. 
 
 
 
 
 
 
 
 
 
 
 
5.

Apply HFC power to the node through power port (40 

– 90VAC).  Verify that the Return Transmitter  

“Normal” 

LED and the 

“Opt. RX TP”  

LEDs illuminate.  

 

Figure 5 

Figure 6 

User Manual 

LBON4000 

LBON4000 April 2013 

Содержание LBON4000 ONU

Страница 1: ...LBON4000 ONU User Manual LBON4000 April 2013...

Страница 2: ...Product Description 1 2 0 Safety Notes 2 3 0 Block Diagram 3 4 0 Specifications 4 5 0 RF Connector Installation 5 6 0 Power Connector Installation 5 7 0 AC Power Director 6 8 0 General Set Up 6 9 0 F...

Страница 3: ...elength laser type and band splits for maximum application FEATURES High RF output level 52 48dBmV per Port for 2 4 Ports GaAsFET Technology provides Low Distortions and Low power consumption Downstre...

Страница 4: ...ly damage the retina of an eye Avoid direct exposure to the laser light source Never apply power to this product if the fiber is neither connected nor terminated Never stare directly into a fiber or a...

Страница 5: ...1 Optical Rx input LED TP Optical Rx input Optical Tx out Optical Receiver Optical Transmitter Laser 20dB TP 20dB TP 20dB TP 20dB TP 20dB TP 20dB TP RF Port 1 RF Port 3 RF Port 2 RF Port 4 FIGURE 1 Du...

Страница 6: ...mW 2 3 4 mW RF Input Level dBmV Dynamic Input Range NPR 38 dB Frequency Range Optional 5 65MHz 5 42 MHz Flatness of Frequency Response f 5 to 42MHz 0 75 dB Input Return Loss f 5 to 42MHz 16 dB Optical...

Страница 7: ...the end of the cable now 6 Insert the KS connector and cable to the Housing base and tighten connector KS connectors should be tightened per manufacturer s specifications 7 Using a Philips screw driv...

Страница 8: ...he total upstream RF signal level from all ports is within the node s specified input range then connect the coaxial cable to the node s RF In Out F port 4 The LBON4000 must be grounded Use a split bo...

Страница 9: ...oint 20dB and with a 0dB pad in ATT3 position place desired attenuator value into EQ1 for desired output tilt 4 Countinuing to monitor Out1 test point 20dB adjust pad value in ATT3 position for the de...

Страница 10: ...dsaybroadbandinc com Resources Tab for a spreadsheet calculator The Total RF return level at the input to the laser should be 34 50dBmv NPR 38dB This can be checked at the Return test point 20dB at th...

Страница 11: ...st ATT5 pad value to insure total return level to the laser is 34 50dBmv Measure the RF levels at the node input using the Rev T P and remember that it is 20dB below the actual signal level Please not...

Отзывы: