5
RF Connector Installation:
1. All RF connectors including the power port connector are standard
KS-type connectors. Refer to Figure 3.
1. Using a
½
-inch wrench, remove port covers from RF ports and power
port on the housing base.
2. The center conductor seizure screws (Phillips screw) are located
through the module. Loosen, but do not remove the seizure screw.
3. Measure the stinger to verify that it is 0.8 inches (20mm). Refer to
Figure 4.
5. If you are going to apply shrink tubing to weatherproof the finished
connection, slip a section of shrink tube over the end of the cable
now.
6. Insert the KS connector and cable to the Housing base and tighten
connector. KS connectors should be tightened per manufacturer’s
specifications.
7. Using a Philips screw driver tighten the seizure screw.
8. Position the shrink tubing over the connector and apply heat to
shrink it in place.
0.8 in
(20mm)
CAUTION!
AC voltages in the range of 40 to 90 V AC. Shut down external
AC power before connecting or disconnecting power cables to the node.
1.
The LBON4000 requires AC input power between 40 and 90 VAC. AC
power is brought into the Node through the dedicated power port.
2.
Follow “RF Connection Installation” section to install Power cable.
Power Cable Installation:
Figure 3
Figure 4