Battery charging

Dos and don’ts

When out and about, your Inogen One

®

 G3 or 

G5 device operates from battery power which 
will discharge over time. You therefore need 
to monitor the device’s battery status and 
keep it charged up as required (the device  
display indicates the estimated remaining  
percentage (%) or minutes of available use).

Ensure that you drain the battery down to 
0% weekly, prior to recharging: this helps the 
battery maintain its full power capacity for 
longer, making it more reliable for you. 

When the concentrator detects that battery 
life is low (<10 mins remaining) a low priority 
alert will sound. When the battery is empty, 
the alert changes to a high priority. When 
battery life is low, do one of the following:

•  Plug the Inogen One

®

 G3 or G5 into an AC  

or DC power source using the AC power 
supply or DC cable

•  If you have a second battery, replace the 

fully-drained battery with it after turning 
off the Inogen One

®

 G3 or G5 (by pressing 

the ON/OFF button). To remove a battery, 
press and hold the battery latch button 
and slide the battery away from the 
concentrator

•  Once the battery is drained to 0%, 

charge the battery or remove it from 
the concentrator

Dos

•  Always ensure you have access to a  

power source to recharge your Inogen 
One

®

 G3 or G5 unit

•  Always use only those power sources  

(AC/DC) supplied with the device

•  Always protect the battery and power 

adapters from fluid spills or drips to avoid 
possible shock hazards

•  Always keep the Inogen One

®

 G3 or G5 

unit at least 10 feet/3.2 metres from hot,  
sparking objects or naked sources of flame.

Don’ts

•  Never block the air intake and exhausts on 

the front of the Inogen One

®

 G3 or G5 unit

•  Never lie the unit on its side during  

operation and do not cover with clothing 
or other materials

•  The Inogen One

®

 G3 or G5 is not designed 

or specified to be used in conjunction with 
a humidifier, nebuliser or connected with 
any other equipment.

•  Never expose the unit to extremes of  

temperature and do not store overnight 
in a car at any time of year (the operating 
temperature of the unit is 5°C to 40°C)

•  Never use oil or grease near or with the 

unit: a spontaneous and violent ignition 

•  If the Inogen One

®

 G3 or G5 is being 

powered by the AC power supply or 
DC power, batteries will charge during 
operation

•  Note: leaving your Inogen One

®

 G3 or G5 

device plugged in past full charge will not 
harm the concentrator or battery.

To ensure your battery is properly charging, 
use the correct AC or DC power cables 
and check that the display shows a battery 
charging symbol (see example on page 21 
for G3 or page 26 for G5). To take care of 
your device, only use Inogen One

®

 G3 or G5 

batteries as supplied by BOC, your home 
oxygen service provider.

Always

•  Store device batteries in a cool, dry place
•  Keep liquids away from batteries.  

If batteries become wet, discontinue  
use immediately and dispose of the  
battery properly

•  If using multiple batteries, make sure that 

each battery is rotated-for-use on a regular 
basis. Batteries should not be left dormant 
for more than 90 days at a time.

may occur if oil, grease or other petroleum 
substances come into contact with  
oxygen under pressure. Keep these  
substances away from the oxygen system, 
tubing, connections and any other  
oxygen source

•  Never use any petroleum-based or other 

lubricants on your hands or person

•  Never allow unauthorised or untrained  

individuals to service the equipment or 
attempt to open the device

•  Never operate the Inogen One

®

 G3 or G5 

unit or accessories in standing water and 
do not submerse these or expose to water. 
Electric shock or damage to the unit may 
result

•  Never expose the rechargeable battery to 

fire or dispose of in a fire. It may explode 
and cause potential injury

•  Never short circuit the battery’s metal  

contacts with metallic objects such as keys or 
coins. It may cause sparks or excessive heat

•  Never disassemble, puncture or crush the 

battery. Rechargeable battery electrolytes 
may be toxic if swallowed and can be  
harmful to skin and eyes. Use of a damaged 
battery may cause personal injury. Always 
keep the battery away from children

•  Avoid touching the recessed electrical 

contacts of the external battery charger; 
damage to contacts may affect charger 
operation.

Important: Please ensure you read all accompanying literature 
supplied to you prior to using your home oxygen equipment. 
In particular, pay attention to the section on not smoking or 
allowing others to smoke near your equipment.

Содержание BOC Inogen One G3

Страница 1: ...Service provided by Portable concentrators Equipment guide...

Страница 2: ...oxygen concentrator works by drawing in air and separating out oxygen from other gases using a filter system This filter traps some gases but allows oxygen to pass through This oxygen now up to 95 pur...

Страница 3: ...are four or five settings 1 to 4 or 1 to 5 pulsed Display backlight button Push this button to turn on the display backlight for better illumination of the device settings The back light turns off aga...

Страница 4: ...le 1 Device location Place your Inogen One G3 device in a wellventilated location so the intake and exhaust vents are clear and unobstructed the position of these can vary as pictured alongside The de...

Страница 5: ...reath and delivers oxygen every time you inhale through your nose even if your breathing rate changes Note A green light will flash on the top of the unit each time a breath is detected Make sure the...

Страница 6: ...10 Portable concentrators Equipment guide 11 Portable concentrators Equipment guide...

Страница 7: ...attery life and errors Display appearance will vary Indicator lights A green light indicates breath detection A yellow light indicates either a change in operating status or a condition that may need...

Страница 8: ...h returns to the upper position 14 15 Portable concentrators Equipment guide Portable concentrators Equipment guide Important Please read the important safeguards in the Dos and don ts section and obs...

Страница 9: ...breaths giving the appearance of a missed breath This may be normal as the Inogen One G5 senses and monitors the changes in your breathing pattern The Inogen One G5 will normally sense the next breat...

Страница 10: ...oil or grease near or with the unit a spontaneous and violent ignition If the Inogen One G3 or G5 is being powered by the AC power supply or DC power batteries will charge during operation Note leavin...

Страница 11: ...display s power status window when the Inogen One G3 is operating on battery power Inogen One G3 Oxygen Concentrator Audible and Visible Signals Audible and Visible Signals Chapter 4 C C C C Meaning B...

Страница 12: ...ghtning bolt indicates that an external power supply is connected C C C Meaning Battery is charging with charge level between 60 and 70 The battery is fully charged and is charging as necessary to mai...

Страница 13: ...conds accompanied with a flashing red light Inogen One G3 high priority alerts The following high priority alert messages are accompanied by a five beep pattern repeated every 10 seconds accompanied w...

Страница 14: ...ogress OR SW Update in progress app only This icon is displayed during all data log transfers and software updates initiated through the Inogen Connect app Data Log transfer success app only This icon...

Страница 15: ...ction Explanation Battery Low Attach Plug Battery power is low with less than 10 minutes remaining Attach external power supply or power down and insert a fully charged battery Replace Columns Column...

Страница 16: ...y a five beep pattern repeated every 10 seconds accompanied with a flashing yellow light Description Display icons Condition action explanation Battery Empty Attach Plug Concentrator has insufficient...

Страница 17: ...and damp clean only Warning do not submerse the Inogen One G3 or G5 or their accessories in water or allow water to enter the case this may lead to electrical shock and or damage Do not use cleaning a...

Страница 18: ...ell battery Flow Control Settings 1 to 4 or 1 to 5 depends on device version Battery duration varies with breath rate flow setting and environmental conditions Weight 2 13 kg 4 7 lbs with single 8 cel...

Страница 19: ...y Road The Surrey Research Park Guildford GU2 7XY England Number 337663 English Register Authorised and regulated by the Financial Conduct Authority register number 715528 BOC is a company name used b...

Отзывы: