Technical Data:
Output volume:
Q
= 0-2,2 cm
3
/stroke, adjustable
Operating pressure:
p
max
= 400 bar,
p
min
= 35 bar
Main line connection:
G
3
/
8
Feed line connection:
G
1
/
4
Technical Data VSG-KR
TYPE
VSG2-KR
VSG4-KR
VSG6-KR
VSG8-KR
Number of outlets
2
4
6
8
L1 (mm)
30,5
62
94
126
L (mm)
44,5
76
108
140
Part no.
620-40015-1
620-40015-3
620-40015-5
620-40015-7