STEP 9
STEP 9
A
B
STEP 9
STEP 9
STEP 13
A
B
C
10 nO
appears in display. Green LED on
PROXY 2
illuminates. Should
2nd proxy be necessary, proceed by pushing
Δ
.
11
Press
ENTER
to confirm and proceed setup for
PROXY 1
.
12
When one sensor is used, press
Δ
until
nO
appears in display.
13
Press
ENTER
to confirm (
Fig. 38 A
).
14 nO
appears again in display. Green LED on
RESERVOIR
illuminates. Setup procedure allows selection of
low level detection.
Push
Δ
and select
nO
if low level detection is not required.
15
Press
ENTER
to confirm. For this example, select low level option
by pressing
Δ
until
YES
appears in display.
16
Press
ENTER
to confirm (
Fig. 38 B
).
17 n-O
(normally open) displays indicating if sensor is normally open
or normally closed. Press
Δ
to choose between
n-O
or
n-C
.
18
Press
ENTER
to confirm choice (
Fig. 39 A
).
19 FE
(fatal error) or
nFE
(nonfatal error) appears in display.
Option
FE
(fatal error) is used to stop pump on low level warning.
Typically used on pumps with reservoir capacities from 0.26 to
2.6 gal
(1 to 10 l)
. It is preferred to stop pump at low level to
maintain layer of grease above pump element area thereby
not allowing air pockets to form around pump element when
filling up reservoir (
Fig. 39 B
).
Option
nFE
(nonfatal error) is recommended on larger pump
reservoirs with substantial distance from pump tube to bottom
of reservoir (
Fig. 39 C
).
20
Press
Δ
to select choice and press
ENTER
to confirm.
Fig. 38
Fig. 39
NOTE
10-second delay occurs on startup when using low level sensor
to ensure paddle assembly is in correct position.
Sensor activates on low level after 10 seconds. Low level
warning displays when unit reaches pause status.
24
25