System Operation (Non-Monitored System)
The key components of the Quicklub Non-Monitored system are:
1.
Pump
with an
Integrated Timer.
The Integrated timer controls the “
On Time
” and “
Off Time
”
of the pump.
2. Divider valve network consisting of a Primary Valve and Secondary Valves with attached
Cycle
Indicator Pin
.
3. A lubrication event is initiated by actuating the pump via the
Integrated Timer
based on a
preset “pause time” or time between lubrication events.
4. The
Pump
dispenses lubricant to the primary divider valve.
5. The
Primary Valve
distributes the lubricant to the secondary valves.
6. The
Secondary Valves
distribute and dispense lubricant to the lubrication points.
7. Lubricant flow through the divider valves actuates the
Cycle Indicator Pin
for a visual
inspection of proper operation.
8. The pump will run for the preset On-Time
9. The controller now begins countdown for the next lubrication event.
2/13/09
6
Non-Monitored System
Secondary
Divider
Valves
Primary
Divider
Valve
Pump
Tubing
Lube Point
Hose
Outlet Fitting
Closure Plug
Cycle Indicator Pin