System Operation (Monitored System)
The key components of the Quicklub Monitored system are:
1.
Pump
with an
Integrated Timer.
The Integrated timer controls the “
Off Time
” of the pump.
2. Divider valve network consisting of a Primary Valve and Secondary Valves with attached
Cycle
Indicator Pin
.
3. A lubrication event is initiated by actuating the pump via the
Integrated Timer
based on a
preset “pause time” or time between lubrication events.
4. The
Pump
dispenses lubricant to the primary divider valve.
5. The
Primary Valve
distributes the lubricant to the secondary valves.
6. The
Secondary Valves
distribute and dispense lubricant to the lubrication points.
7. Lubricant flow through the divider valves actuates the
Cycle Indicator Pin
for a visual
inspection of proper operation.
8. The pump will run until the proximity switch reads one full cycle of the piston. The proximity
switch can be attached to any block outlet in the system.
9. The timer now begins countdown for the next lubrication event.
10. The Pushbutton/Fault light will blink if the pump reservoir is low on grease or if there is a
blockage in the system.
2/13/09
7
Primary
Divider
Valve
R3 Valve
Secondary
Divider
Valves
Pushbutton/
Fault Light
Pump
Proximity
Sensor
Hose
Monitored System
Lube Point
Hose