Page Number 14 of 28
QLS 311
Subject
to
modifications
2.1B-38008-A01
Form 403074
Installation and Operation Instructions
Programming mode
Setting number of cycles P3 (Option)
Important:
Settings are only possible in connection with
progressive divider block SSV 6
or SSV 8
(connected as
a main divider block).
* Press the button. The selection of
P3
(cycles) is
displayed.
* Factory setting.......................................................1 cycle
* Max.......................................................................3 cycles
* Press the button and program the number of cycles (2,
3) in accordance with the desired dosage.
Completing the programming
* Press the button.
P-
is displayed.
Important:
In order to avoid a wrong programming, make
sure to always carry out the programming order completely,
i. e. setting of P1 (hours), P2 (minutes) , P3 (number of
cycles) and P- (programming end).
* Complete the programming by pressing the button, see
fig.
Note: If the displayed button is not pressed within 30
seconds, programming mode remains in the previously set
time.
Important:
After completition of the programming order,
check the adjustment of the pause time in the operating
mode, again (see page 12).
Display
press
press
Fig. 29 - Display in programming mode
Programming options - Pause time:
P1
0 99 hours
P2
0 59 minutes
Min. pause time
20 minutes
Max. pause time
99 hours 59 minutes
Setting hours P1
* Settings are made in one direction: 0, 1, 2, 3, ..... 99 h
Button pressed once.......................increases by 1 hour
Button pressed continuously................quick sequence
The fields hourand minutesare indicated by a
decimal point
on the
right - hand
for the
hours
and on
the left - hand
for
the minutes.
Setting minutes P2
* Settings are made in one direction: 0, 1, 2, 3....59
minutes
Button pressed once.......................increases by 1 minute
Button pressed continuously....................quick sequence
Note: The minimum pause time begins at 20 minutes.
When pause time is programmed less than 20 minutes , the
display automatically shows
.20
. Precondition is that you
have to complete the programming order in the following
steps: setting of P1, P2, P3 and P-.
* To access to the programming mode,
press both but-
tons
at the same time
for between
4 seconds.
³
4 sec
4215a99
4222a99
4214a99
4222a99
4216a99
4217a99
4222a99
4214a99
4214a99
4214a99
4222a99
4222a99
4220a99
4218a99
4219a99
4221a99
4208a99