LFC 3000 User’s Manual

Series “A”

System Menu

Hose Calibration

This prompt is offering the possibility to correct the delay of

the solenoid valve shut-off.

When an operator presets a quantity of fluid to be dis-

pensed,  the  system  will  automatically  close  the  solenoid

valve when the preset quantity has been reached. The LFC

3000 counts the pulses coming from the pulse transmitter.

Assuming that the pulse transmitter type is 100 pulses per

liter, the calibration procedure will be as follows;

Preset quantity:

4 liters = 400 pulses

Quantity  dispensed:

4.1 lit. = 410 pulses

Difference:

0.1 lit. = 10 pulses

10 will be the calibration factor to enter in the system.

ENTER

Select Hose

01

ENTER

Pulse count

10

ENTER

System Menu

Change I/O ID

By default all the I/O units have the same address (ID)

Number  0  corresponding  to  solenoid  drivers  (hose  reels)  1

to 8. For the installation with multi I/O units (more than 8

hosereels), each I/O must have its own address to be

identified by the network.

Power up each I/O successively and change their address.

For example ID Number 1 for solenoid drivers (hose reels)

9 to 16.

ENTER

Changer ID I/O

From 0 to 1

ENTER

The network communicates now with this I/O unit 1 for

hoses 9 to 16.

System Menu

Exit

ENTER

Return to Customer Configure Menu at the exit prompt. To

return to the User screen, press twice ENTER.

TRANSACTION CODES

Explanations for the transaction end codes

printed on each transaction ticket:

0 Means that the transaction has been stopped after

the inactive Timeout:

- it’s normal in free dispense mode

- The preset quantity has not been totally dispensed

1 In preselect mode, the preset quantity has been

totally  dispensed:  Completed

2 Input Error in the pulses sequence: for quadrature

pulsers  only

3 Count  Error:  missing  pulse  in  quadrature  pulsers

only

4 It means that the power has been shut down during

the transaction: Power down

5 The transaction has been stopped by the emergency

procedure (“…”): System inactive

6 IOP Error: Microprocessor Error

7 Unauthorized transaction: for approved systems only,

quantity dispensed between 0.5Lt and 100Lt.

Содержание LFC 3000

Страница 1: ...Page Section F60 2 Form 403082 June 2002 LFC 3000 User s Manual Series A...

Страница 2: ...the LFC3000 where the cord will be walked on 10 An extension cord is not recommended for use with the LFC3000 If you use an extension cord make sure that the total of the ampere ratings on the product...

Страница 3: ...with any I O module A job number a hose number and the preset amount must be entered The technician then begins dispensing the product The amount of product dispensed is displayed on the remote displ...

Страница 4: ...f fluids dispensed and totals All the reports are printed on the report printer as configured in the system configuration menu TECHNICALDATA Network specifications The LFC 3000 operates with a CAN Bus...

Страница 5: ...lable By user Report by user Enter the user s number By hose Report by hose Enter the hose s number By product Report by product Enter the product s number All trans actions All Reports Exit Superviso...

Страница 6: ...ng the alphanumeric keypad ENTER The system goes back to the prompt Products Customer Menu Hose All your dispensing points hoses must be linked to the tank it is dispensing from ENTER Enter Hose 01 En...

Страница 7: ...use he is work ing in the free dispense mode When choosing this dura tion bear in mind that this should be long enough for your worker to verify the oil level on the dip stick Enter the maximum number...

Страница 8: ...22 for the System Menu Customer Menu Exit ENTER Return to the supervisor menu prompt To return to the User Screen press ENTER again SYSTEMMENU The System Configuration Menu is accessible through all t...

Страница 9: ...to select the address ENTER Ticket A Address None ENTER There is no ticket A printer on the system Use Up Down keys to select ENTER Every display is delivered with dip switches on the PC board See In...

Страница 10: ...or PIN ENTER System Cfg PIN LFC 3000 operates all the hose reels simultaneously or one hose reel at a time When the system is configured in simultaneous mode you will be able to dispense on all the di...

Страница 11: ...have its own address to be identified by the network Power up each I O successively and change their address For example ID Number 1 for solenoid drivers hose reels 9 to 16 ENTER Changer ID I O From...

Страница 12: ...mer Menu Exit Customer Menu Config Syst Customer Menu Diagnostic Customer Menu Init Timeout Customer Menu Set Cust PIN Customer Menu Set Language Enter Enter System Menu _ _ _ _ System Menu Test Mode...

Отзывы: