System Menu

Set Ticket B Adr.

To fulfill all the needs of the garage supervisor, LFC 3000

offers also the flexibility to print a copy of the transaction

tickets. All the printers must be connected through the serial

port and be Epson emulated. This printer can be the main

printer. This instruction must be done on EACH keypad. The

factory default setting is ticket B address on keypad 0.

Ticket B Address

I/O Control Unit

ENTER: The ticket B printer is connected on the I/O unit

(ID=0)

Use Up / down keys to select.

Ticket B Address

None

ENTER: There is no ticket B printer on the system.

Use Up / Down keys to select

Ticket B Address

Keypad x

ENTER: The ticket B printer is connected on the keypad

Number x.

Use Up / Down keys to select the address

ENTER

System Menu

Set System PIN

The system PIN code can be modified. Only numerical PIN

is accepted by the system. If the system PIN Number has

been forgotten, it will be necessary  to reset the system and

re-configure.  See Instruction Manual, under Troubleshoot-

ing, “Lost Supervisor PIN.”

ENTER

System Cfg PIN

****

LFC 3000 operates all the hose reels simultaneously or one

hose reel at a time.  When the system is configured in

simultaneous mode, you will be able to dispense on all the

different hoses at the same time.

The factory default setting is simultaneous.

System Menu

Set Simultaneous Mode

ENTER

Set Simultaneous Mode

Non-Simultaneous

Use Up / down keys to select.

Set Simultaneous Mode

Simultaneous

In a multi I/O system without PC, this parameter must

programmed and must be the same on each I/O

ENTER

System Menu

Pulses per Liter

LFC 3000 is designed to register pulses from 1 to 255 per

liter. Refer to the type of pulse transmitter.  To change to

“pulses per quart” see user menu, “Set Language”, change

to American English.

Pulse per Liter

100

In a multi I/O system without PC, this parameter must

programmed and be the same and on each I/O.

ENTER

System Menu

Max. Dispense

ENTER

Select Hose

0

Max. Dispense

_ 100

ENTER the maximum quantity that will be allowed to be

dispensing  on  the  selected  hose.

Then press ENTER and do the same for the other hoses.

System Menu

Decimal Place

Decimal Place

1

You can choose the place of the decimal. You only have 1 or

2 (use the Up / down arrow key).

( You also have to change physically the jumper located in

the display). ENTER

Содержание LFC 3000

Страница 1: ...Page Section F60 2 Form 403082 June 2002 LFC 3000 User s Manual Series A...

Страница 2: ...the LFC3000 where the cord will be walked on 10 An extension cord is not recommended for use with the LFC3000 If you use an extension cord make sure that the total of the ampere ratings on the product...

Страница 3: ...with any I O module A job number a hose number and the preset amount must be entered The technician then begins dispensing the product The amount of product dispensed is displayed on the remote displ...

Страница 4: ...f fluids dispensed and totals All the reports are printed on the report printer as configured in the system configuration menu TECHNICALDATA Network specifications The LFC 3000 operates with a CAN Bus...

Страница 5: ...lable By user Report by user Enter the user s number By hose Report by hose Enter the hose s number By product Report by product Enter the product s number All trans actions All Reports Exit Superviso...

Страница 6: ...ng the alphanumeric keypad ENTER The system goes back to the prompt Products Customer Menu Hose All your dispensing points hoses must be linked to the tank it is dispensing from ENTER Enter Hose 01 En...

Страница 7: ...use he is work ing in the free dispense mode When choosing this dura tion bear in mind that this should be long enough for your worker to verify the oil level on the dip stick Enter the maximum number...

Страница 8: ...22 for the System Menu Customer Menu Exit ENTER Return to the supervisor menu prompt To return to the User Screen press ENTER again SYSTEMMENU The System Configuration Menu is accessible through all t...

Страница 9: ...to select the address ENTER Ticket A Address None ENTER There is no ticket A printer on the system Use Up Down keys to select ENTER Every display is delivered with dip switches on the PC board See In...

Страница 10: ...or PIN ENTER System Cfg PIN LFC 3000 operates all the hose reels simultaneously or one hose reel at a time When the system is configured in simultaneous mode you will be able to dispense on all the di...

Страница 11: ...have its own address to be identified by the network Power up each I O successively and change their address For example ID Number 1 for solenoid drivers hose reels 9 to 16 ENTER Changer ID I O From...

Страница 12: ...mer Menu Exit Customer Menu Config Syst Customer Menu Diagnostic Customer Menu Init Timeout Customer Menu Set Cust PIN Customer Menu Set Language Enter Enter System Menu _ _ _ _ System Menu Test Mode...

Отзывы: