![Lincoln IMPINGER 1000 series Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/lincoln/impinger-1000-series/impinger-1000-series_service-manual_1917748056.webp)
Impinger I -–1000 Series Service Manual - Domestic
56
IGNITION CONTROL - REPLACEMENT
1.
Remove control panel top and front cover.
2.
Loosen two (2) locking screws on front cover of relay (approx. 1/2 turn).
3.
Remove front portion of relay by pulling straight out (rocking motion).
4.
Remove wires from plug-in terminal strip, note wire numbers and locations.
5.
Remove two (2) screws from mounting bracket and remove.
6.
Reassemble in reverse order (NOTE: Plug in terminal strip is polarized and will only
allow relay to plug in one direction, make sure manual reset button lines up with access
hole in front cover.) Check system operation.
HIGH - LIMIT THERMOSTAT - REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove conveyor and fingers.
3.
Remove capillary bulb from wire form in oven chamber and pull through tube into control box.
4.
Remove two (2) wires from thermostat, note wire numbers and location for reinstallation.
5.
Remove screws from bracket and remove thermostat.
6.
Reassemble in reverse order making sure capillary tube is placed securely in the wire form.
NOTE:
Depress reset button to insure thermostat is set for operation.
SPARK GENERATOR – REPLACEMENT
1.
Remove control panel top and front cover.
2.
Loosen two (2) locking screws (approx. 1/2 turn) on ignition control and remove front
portion of relay exposing terminal strip.
3.
Remove two (2) wires for spark generator.
4.
Unplug connector on bottom of spark generator.
5.
Remove two (2) mounting screws and remove generator assembly.
6.
Reassemble in reverse order and check system operation.
SOLENOID VALVE – REPLACEMENT
1.
Remove control panel top and front cover.
2.
Disconnect pipe union just above gas valve assembly.
3.
Disconnect two (2) wires from solenoid, note wire number and location for reinstallation.
4.
Remove four (4) nuts from main orifice burner bracket and remove assembly.
5.
Replace valve and reassemble in reverse order.
6.
After assembly, check all fittings for leaks and check system operation.
FLOW
BURNER ALARM - REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove two (2) wires from alarm, note wire numbers and location.
3.
Remove retainer cover from alarm and remove assembly from mounting bracket.
4.
Reassemble in reverse order and check.
Содержание IMPINGER 1000 series
Страница 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Страница 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Страница 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Страница 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Страница 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Страница 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Страница 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Страница 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Страница 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Страница 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Страница 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Страница 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Страница 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Страница 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Страница 65: ...Impinger I 1000 Series Service Manual Domestic 65 BLOW UP 1000 1001 1050 1051 1004 1005 S N 100 TO 4389 ...
Страница 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Страница 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Страница 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Страница 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Страница 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Страница 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Страница 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Страница 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Страница 83: ...Impinger I 1000 Series Service Manual Domestic 83 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE ...
Страница 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Страница 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Страница 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Страница 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Страница 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Страница 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...