Impinger I -–1000 Series Service Manual - Domestic
54
Dip Switch
1
2
3
4
5
6
7
8
9
10
TYPE I
OFF
OFF
OFF
ON
OFF
OFF
TYPE II
OFF
OFF
OFF
OFF
OFF
OFF
TYPE III
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
NOTE: When on 50 HZ power, dip switch #2 must be "ON"
With power ON turn time and temperature cal. pot. fully counterclockwise.
Display should read: (Wait 15-20 seconds)
TYPE I 9:30 + 10 sec.475 + 10°F
TYPE II 9:20 + 10 sec. HHH
TYPE III 9:35 + 10 sec. 635 + 10°F
Turn time and temp. cal. pot. fully clockwise.
Display should read: (Wait 15-20 seconds)
TYPE I 10:20 + 10 sec. 615 + 10°F
TYPE II 10:10 + 10 sec. 475 + 10°F
TYPE III 10:20 + 10 sec. 475 + 10°F
Turn time pot. to 10:00 minutes and temp. pot. to 540°F.
Time reading 10:00 ± 5 seconds.
Temperature reading should be steady at 540°F + 10°F.
If these readings are not achieved, replace display.
NOTE:
After simulator test is completed, the oven Time/Temperature Display must be re-calibrated.
SWITCH REPLACEMENT (FAN, HEAT, CONVEYOR)
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove switch access cover.
4.
Depress the spring clips on the sides of the switch and push out.
5.
Remove wires from back of switch. Note wire number and location.
6.
Install new switch in reverse order and check.
SWITCH REPLACEMENT - (FAN SWITCH UPDATE)
INSTALLATION OF DOUBLE POLE FAN SWITCH #369260 IN PLACE OF SINGLE POLE
FAN SWITCH #350705
NOTE:
This change is not necessary for proper operation of oven nor is it
permissible to change under warranty. Should be changed only at
customer's request and their agreement to pay your bill.
ADVANTAGE:
Allows time/temp. display, in older models, to operate same as current
production models. Also allows locked time/temp. display (caused by
voltage surge, interruption or spike) to be reset by fan switch rather than
circuit breaker.
IDENTIFICATION: To determine which fan switch you have, observe if temperature displays
stays on during cooling down. If it stays on , you have the single pole
switch. If it goes out as soon as fan switch is turned off you have the double
pole switch.
REPLACEMENT: Replace single pole switch # 350705.
Install double pole switch # 369260.
Disconnect lead indicated by # in proper diagram and reroute as shown.
Install jumper lead indicated by * in proper diagram.
Reapply all other leads as removed.
Содержание IMPINGER 1000 series
Страница 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Страница 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Страница 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Страница 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Страница 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Страница 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Страница 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Страница 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Страница 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Страница 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Страница 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Страница 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Страница 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Страница 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Страница 65: ...Impinger I 1000 Series Service Manual Domestic 65 BLOW UP 1000 1001 1050 1051 1004 1005 S N 100 TO 4389 ...
Страница 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Страница 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Страница 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Страница 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Страница 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Страница 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Страница 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Страница 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Страница 83: ...Impinger I 1000 Series Service Manual Domestic 83 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE ...
Страница 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Страница 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Страница 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Страница 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Страница 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Страница 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...