![Lincoln IMPINGER 1000 series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/lincoln/impinger-1000-series/impinger-1000-series_service-manual_1917748003.webp)
Impinger I -–1000 Series Service Manual - Domestic
3
SEQUENCE OF OPERATIONS 1000/1001/1004/1005/1200/1201/1204/1205
MODEL 1000 - 120/230 VAC - 60HZ - NATURAL GAS
MODEL 1001 - 120/230 VAC - 60HZ - L.P. GAS
MODEL 1004 - 120/230 VAC - 60HZ - NATURAL GAS
MODEL 1005 - 120/230 VAC - 60HZ - L.P. GAS
MODEL 1200 - 120/230 VAC - 60HZ - NATURAL GAS/DUAL BELT
MODEL 1201 - 120/230 VAC - 60HZ - L.P. GAS/DUAL BELT
MODEL 1204 - 120/230 VAC - 60HZ - NATURAL GAS/DUAL BELT
MODEL 1205 - 120/230 VAC - 60HZ L.P.GAS/DUAL BELT
POWER SUPPLY
Electrical Power to be supplied to the Oven by a four conductor service. . Voltage
from the black conductor to the white conductor is 120 VAC.
Black conductor is Hot
Red conductor is Hot
White conductor is Dedicated Neutral
Green conductor is Ground
CONTROL BOX AUTO
COOL DOWN
When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will
interrupt power to the Cooling Fan when the Control Box temperature falls to 100°F +
3°.
MAIN FAN CIRCUIT
Electrical power is permanently supplied to the normally open contacts of the Double
Pole Main Fan Relay, the Cooling Fan Thermostat, the normally open Main Fan
Switch, and the normally open Cool Down Thermostat (thermostat closes at 160°F
and opens at 140°F). Closing the Main Fan Switch energizes the coil of the Relay.
The normally open contacts now close, energizing the Main Fan Motor through (2)
10A fuses, and the Cooling Fan. Closing the Fan Switch also supplies power to the
Hour Meter (hour meter discontinued after S/N 3484), the 12.6 VAC Transformer, the
Burner and Conveyor Switches.
TRANSFORMER (12.6
VAC)
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The
voltage from each leg of the Transformer's secondary to the center tap should be
one half of the secondary voltage.
BURNER CIRCUIT
Closing the Fan Switch and the normally open Burner Switch supplies 120 VAC
through the Air Pressure Switch, to the normally open contacts of the Burner Motor
Relay, and the primary of the 24 VAC Step Down Transformer. The Transformer
secondary supplies 24 VAC (through a 1A fuse on Model 1004 and 1005) to the
Relay Coil (the normally open contacts close within 30 seconds), and the normally
open Centrifugal Switch. When the Relay contacts close, the Burner Blower Motor is
energized. As this motor reaches approximately1600 R.P.M., its internal centrifugal
switch closes, supplying 24 VAC to the Gas Control Valve. When the Gas Control
Valve is supplied with 24 VAC the pilot valve is energized, and the ignitor circuit is
energized. Ignition should now occur. After pilot flame is proven, the main gas valve
is energized. The Burner Indicator Light is also energized.
CONVEYOR DRIVE(S/N
100 to 4389)
Closing the Fan Switch and the normally open Conveyor Switch supplies 120 VAC
through a 3A Fuse, to the Motor Control Board. AC volts are converted to D.C. volts
and are supplied to the Conveyor motor at board terminals A1 and A2 through a
D.P.D.T. Reversing Switch. Adjustment of the Speed Control Potentiometer (500
ohm, 10 turn) will change resistance at terminals S1, S2, and S3 varying the D.C.
voltage to the motor. The speed of the Conveyor Motor will increase or decrease as
the D.C. voltage from the Motor Control Board increases or decreases respectively.
(S/N 4390 and UP)
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to
the Motor Control Board. AC volts are converted to DC volts and are supplied to the
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control
Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and
P3 varying the DC voltage to the motor. The speed of the conveyor motor will
increase or decrease as the DC voltage from the board increases or decreases
respectively. As the motor turns, it drives both the reducer gearbox and the tach.
Содержание IMPINGER 1000 series
Страница 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Страница 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Страница 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Страница 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Страница 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Страница 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Страница 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Страница 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Страница 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Страница 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Страница 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Страница 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Страница 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Страница 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Страница 65: ...Impinger I 1000 Series Service Manual Domestic 65 BLOW UP 1000 1001 1050 1051 1004 1005 S N 100 TO 4389 ...
Страница 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Страница 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Страница 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Страница 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Страница 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Страница 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Страница 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Страница 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Страница 83: ...Impinger I 1000 Series Service Manual Domestic 83 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE ...
Страница 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Страница 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Страница 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Страница 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Страница 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Страница 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...