Page Number - 3
Form 403750
FlowMaster™ Rotary Driven Hydraulic Pump
Do not exceed 3,500 PSIG (241 bar) maximum supply inlet
hydraulic pressure. Exceeding the rated pressure may result
in damage to system components and personal injury.
3XPS3HUIRUPDQFHDQG6SHFL¿FDWLRQ
Supply inlet hydraulic pressure,
maximum, PSIG (bar) -
3,500 (241)
Operating working hydraulic
pressure , PSIG (bar)
-
300 to 450 (20 to 32).
Hydraulic Inlet Flow,
GPM (l/min) -
Fixed at 2 GPM.
Pump Ratio with manifold -
9:1 at low inlet pressure
(300 to 350 psi [20 to 25
EDU@DQGORZLQOHWÀRZ
(below 2 gpm [7 lpm])
Pump
ratio
approaches
11.0:1 ratio at higher
LQOHWSUHVVXUHDQGÀRZ
Operating Temperature, ºF (ºC)-
-20 to +150 (-29 to 65)
Grease output at 2 GPM (Fixed)-
6 in³/min (at 0°F) to
14 in³/min (at 80°F)
*Solenoid valve with manual override standard.
Hydraulic
Fluid Inlet
Hydraulic
Fluid Return
to Tank
Solenoid Valve
(Items 34* & 35)
Pressure Reducing
Valve (Item 38)
Vent
Valve
Pressure Gauge (Item 32)
Model 85676 only.
Flow Control
Valve (Item 39)
Hydraulic Motor
(Item 42)
Material
Outlet
Illustration 1
in during the previous stroke is transferred through the outlet
check and discharged to the outlet port. Typical output of the
pump is shown on page 4.
Appropriate Use
$OOSXPSPRGHOVDUHH[FOXVLYHO\GHVLJQHGWRSXPSDQG
dispense lubricants using hydraulic power.
7KHPD[LPXPVSHFL¿FDWLRQUDWLQJVVKRXOGQRWEH
exceeded.
$Q\RWKHUXVHQRWLQDFFRUGDQFHZLWKLQVWUXFWLRQVZLOO
result in loss of claims for warranty and liability.
Illustration 2
24VDC Connections
No Connection to
Center Lug
Solenoid Valve
Operating Voltage, VDC -
24
Hydraulic Inlet Port, In -
SAE
4
Tank Return Port, In -
SAE
6
Pump Outlets, In -
1/4
NPTF
Maximum Hydraulic
Fluid Temperature, ºF, (ºC) -
250 (121)
Weight, Lbs (Kg) -
36
(16)