background image

Models 85622, 85628, 85626, 85637 Non-Metallic-REV1007 

 Page 21

Safe aIr

exhaUSt

DISPOSaL

area

PUMP INStaLLatION area

1"  DIaMeter aIr

exhaUSt PIPINg

1"  DIaMeter aIr

exhaUSt PIPINg

1"  DIaMeter aIr

exhaUSt PIPINg

MUffLer

LIQUID

LeVeL

SUCtION

LINe

LIQUID

LeVeL

SUCtION

LINe

MUffLer

MUffLer

PUMPINg hazarDOUS LIQUIDS

When a diaphragm fails, the pumped 

liquid  or  fumes  enter  the  air  end  of 
the  pump.  Fumes  are  exhausted  into 
the  surrounding  environment.  When 
pumping hazardous or toxic materials, 
the  exhaust  air  must  be  piped  to  an 
appropriate area for safe disposal. See 
illustration #1 at right.

This  pump  can  be  submerged  if 

the  pump  materials  of  construction 
are  compatible  with  the  liquid  being 
pumped. The air exhaust must be piped 
above the liquid level. See illustration #2 
at right. Piping used for the air exhaust 
must not be smaller than 3/8" diameter. 
Reducing the pipe size will restrict air 
flow  and  reduce  pump  performance. 
When the pumped product source is at 
a higher level than the pump (flooded 
suction  condition),  pipe  the  exhaust 
higher  than  the  product  source  to 
prevent siphoning spills. See illustration 
#3 at right.

CONVertINg  the  PUMP  fOr 
PIPINg the exhaUSt aIr

The following steps are necessary to 

convert the pump to pipe the exhaust 
air away from the pump.

Use  a  #8 Torx  or  flat  screwdriver  

to remove the four self-tapping screws 
(item 1-J) (Plastic Valves). Use a Phillips 
screwdriver  to  remove  four  machine 
screws (item 1-I) (Aluminum Valves).

Remove the muffler cap and muffler. 

The air distribution valve body has 3/8" 
NPT threads for installation of alternate 
mesh or sound dampening mufflers or 
piped exhaust.

 

IMPOrtaNt  INStaLLatION NOte:  

The  manufacturer  recommends 

installing a flexible hose or connection 
between  the  pump  and  any  rigid 
plumbing. This  reduces  stresses  on 
the  molded  plastic  threads  of  the  air 
exhaust  port.  Failure  to  do  so  may 
result in damage to the air distribution 
valve body.

Any  piping  or  hose  connected  to 

the  pump’s  air  exhaust  port  must  be 
physically supported. Failure to support 
these connections could also result in 
damage  to  the  air  distribution  valve 
body

.

CONVerteD exhaUSt ILLUStratION

Illustration #1

Illustration #2

Illustration #3

To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]

Содержание 85622

Страница 1: ...te Repair Parts List for Dual Port Suction Model 85637 13 Air Valve Assembly Drawing and Parts List 14 Air Valve Assembly Servicing 15 Pilot Valve Servicing Assembly Drawing and Parts List 16 Intermed...

Страница 2: ...To order call 1 800 548 1191 or visit www partdeal com info partdeal com...

Страница 3: ...flex life Excellent abrasion resistance 275 F 40 F 135 C 40 C Virgin PTFE Chemically inert virtually impervious Very few chemicals are known to react chemically with PTFE molten alkali metals 220 F 3...

Страница 4: ...13 14 15 16 2 1 0 CAPACITY U S Gallons per minute Liters per minute 100 90 2 3 5 4 7 80 70 60 50 40 30 20 10 10 20 30 40 50 60 0 0 BAR PSI HEAD 1 2 3 4 5 6 7 0 30 20 25 10 15 5 9 1 6 7 6 3 4 5 1 5 NPS...

Страница 5: ...Muffler 3 8 NPT Exhaust Port For Optional Muffler Styles or Piping Exhaust Air In Submerged Applications Discharge Port 1 2 NPT Internal 1 NPT External Manifold Can Rotate 90 From Vertical Centerline...

Страница 6: ...lated Muffler 3 8 NPT Exhaust Port For Optional Muffler Styles or Piping Exhaust Air In Submerged Applications Discharge Port 1 2 NPT Internal 1 NPT External 44mm Manifold Can Rotate 90 From Vertical...

Страница 7: ...n and strain to the pumping system A surge suppressor is recommended to further reduce pulsation in flow Air Supply Air supply pressure cannot exceed 125 psi 8 6 bar Connect the pump air inlet to an a...

Страница 8: ...CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure INStaLLatION gUIDe Top Discharge ball Valve Unit To order call...

Страница 9: ...rge suppressor What to Check Blocked air exhaust muffler Corrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Chec...

Страница 10: ...scharge piping and all other openings and connections Be certain the air supply is locked out or made non operational so that it cannot be started while work is being done on the pump Be certain that...

Страница 11: ...Models 85622 85628 85626 85637 Non Metallic REV1007 Page 9 This page left intentionally blank To order call 1 800 548 1191 or visit www partdeal com info partdeal com...

Страница 12: ...3 WET END KIT Santoprene Diaphragms Nitrile Spacer Gaskets Santoprene Check Balls PTFE Seats and PTFE Seals 271872 WET END KIT Santoprene Diaphragms PTFE Overlay Diaphragm PTFE Check Balls PTFE Seats...

Страница 13: ...ong 4 271992 271992 271992 14 Outer Chamber 2 271985 271985 271985 15 Diaphragm 2 252907 252907 271865 16 Overlay Diaphragm 2 252908 17 Suction Elbow 2 252909 252909 252909 18 Discharge Elbow 2 271994...

Страница 14: ...Drawing Dual Port Suction Model 85637 12 22 1 12 12 32 29 26 7 30 31 6 28 15 27 14 2 34 25 9 5 17 25 11 34 2 18 10 9 33 10 33 10 25 25 21 3 20 8 12 10 25 25 4 23 13 ILLUSTRATION SHOWS DIRECTION OF DI...

Страница 15: ...20 x 1 25 long 8 271991 13 Hex Flange Capscrew 5 16 18 x 88 long 8 271992 14 Outer Chamber 2 271985 15 Diaphragm 2 271865 17 Suction Elbow NPT 2 275810 18 Discharge Elbow 2 271994 20 Air Inlet Gasket...

Страница 16: ...arts list Item Part Number Description Qty 1 272836 Air Valve Assembly 1 1 A 273051 Body Air Valve 1 1 B 252929 Sleeve and Spool Set 1 1 C 252927 O Ring 8 1 E 273046 End Cap 2 1 F 273047 O Ring 2 1 G...

Страница 17: ...ed clerance Sleeves and spools cannot be interchanged STEP 3 Reassembly of the air distribution valve Install one end cap with o rings items 1 E 1 C and 1 F into one end of the air valve body item 1 A...

Страница 18: ...ricate outside diameter of the sleeve and o rings Then carefully insert sleeve into valve body Take CAUTION when inserting sleeve not to shear any o rings Install retaining ring to sleeve Generously l...

Страница 19: ...ach end of the intermediate cavity Inspect for wear or damage Replace plunger as needed Apply a light coating of grease to each o ring and re install the plungers in to the bushings Push the plungers...

Страница 20: ...9 15 27 14 13 31 6 28 15 16 27 14 11 25 11 13 15 16 27 14 13 31 6 15 14 11 25 11 13 15 13 286 116 000 only 14 Use With TPE Diaphragms Only 31 6 28 19 15 27 14 11 25 11 13 19 15 27 14 13 31 6 28 15 16...

Страница 21: ...ters 120 in lbs Santoprene 13 56 Newton meters Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate for stress relaxation in the clamped assembly Step 5 Ins...

Страница 22: ...pherical surface The check valve seats items 34 should be inspected for cuts abrasive wear or embedded material on the surfaces of both the external and internal chamfers The spherical surface of the...

Страница 23: ...the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right Converting the pump for piping the exhaust air The following steps are necessary to convert the pump...

Страница 24: ...ive 98 37 EC Safety of Machinery This product has used EN 809 Pumps and Pump Units for Liquids Common Safety Requirements harmonized standards to verify conformance Signature of authorized person Date...

Отзывы: