background image

Models 85622, 85628, 85626, 85637 Non-Metallic-REV1007 

 Page 15

aIr DIStrIbUtION VaLVe  
SerVICINg 

To  service  the  air  valve  first  shut 

off the compressed air, bleed pressure 
from the pump, and disconnect the air 
supply line from the pump.

 
SteP  #1:  See  COMPOSITE 

REPAIR PARTS DRAWING.

Using  a  3/8"  wrench  or  socket, 

remove the four hex flanged capscrews 
(item 12). Remove the air valve assembly 
from the pump.

 

SteP  #2:  Disassembly  of  the  air 

valve.

To  access  the  internal  air  valve 

components  first  remove  the  two  end 
cap  retainers  (item  1-G)  by  inserting 
a  small  flat  screwdriver  into  the  two 
slotted grooves on the valve body and 
gently lifting the retainers out.

Next remove the two end caps (item 

1-E) by grasping the pull tab with finfer 
and thumb or pliers and tugging. Inspect 
the two o-rings (items 1-C and 1-F) on 
each end cap for wear or cuts. Replace 
the o-rings if necessary.

Remove the spool (part of item 1-

B)  from  the  sleeve.  Be  careful  not  to 
scratch or damage the outer diameter 
of  the  spool.  Wipe  spool  with  a  soft 
clean  cloth  and  inspect  for  scratches 
or abrasive wear.

Inspect  the  inner  diameter  of  the 

sleeve  (part  of  item  1-B)  for  dirt, 
scratches,  or  other  contaminants. 
Remove  the  sleeve  if  needed  and  
replace  with  a  new  sleeve  and  spool 
set  (item  1-B). 

Note: The  sleeve  and 

spool set is match-ground to a specified 
clerance. Sleeves and spools cannot be 
interchanged.

SteP  #3:  Reassembly  of  the  air 

distribution valve. 

Install  one  end  cap  with  o-rings 

(items 1-E, 1-C, and 1-F) into one end of 
the air valve body (item 1-A). Insert one 
end cap retainer (item 1-G) into the two 
smaller holes, align with groove in the 
end cap, and push until the closed end 
of the retainer is below the flat surface 
of the valve body.

Remove the new sleeve and spool 

set  (item  1-B)  from  the  plastic  bag. 
Carefully  remove  the  spool  from  the 
sleeve.  Install  the  six  o-rings  (item  1-
C) into the six grooves on the sleeve. 
Apply a light coating of grease to the 
o-rings before installing the sleeve into 
the  valve  body.  Align  the  slots  in  the 
sleeve with the slots in the valve body. 
Insert  the  spool  into  the  sleeve.  Be 
careful  not  to  scratch  or  damage  the 
spool during installation. Push the spool 
in until the pin touches the end cap on 
the opposite end.

Install  the  remaining  end  cap  with  

o-rings and retainer.

Fasten the air valve assembly (item 

1)  and  gasket  (item  23)  to  the  pump, 
using the four hex flanged capscrews 
(item 12). 

Connect the compressed air line to 

the pump. The pump is now ready for 
operation.

Read these instructions 
completely,  before  in- 
stallation  and  start-up. 
It is the responsibility of 
the purchaser to retain 

this  manual  for  reference.  Failure  to 
comply with the recommendations stated 
in this manual will damage the pump, and 
void factory warranty.

IMPOrtaNt

To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]

Содержание 85622

Страница 1: ...te Repair Parts List for Dual Port Suction Model 85637 13 Air Valve Assembly Drawing and Parts List 14 Air Valve Assembly Servicing 15 Pilot Valve Servicing Assembly Drawing and Parts List 16 Intermed...

Страница 2: ...To order call 1 800 548 1191 or visit www partdeal com info partdeal com...

Страница 3: ...flex life Excellent abrasion resistance 275 F 40 F 135 C 40 C Virgin PTFE Chemically inert virtually impervious Very few chemicals are known to react chemically with PTFE molten alkali metals 220 F 3...

Страница 4: ...13 14 15 16 2 1 0 CAPACITY U S Gallons per minute Liters per minute 100 90 2 3 5 4 7 80 70 60 50 40 30 20 10 10 20 30 40 50 60 0 0 BAR PSI HEAD 1 2 3 4 5 6 7 0 30 20 25 10 15 5 9 1 6 7 6 3 4 5 1 5 NPS...

Страница 5: ...Muffler 3 8 NPT Exhaust Port For Optional Muffler Styles or Piping Exhaust Air In Submerged Applications Discharge Port 1 2 NPT Internal 1 NPT External Manifold Can Rotate 90 From Vertical Centerline...

Страница 6: ...lated Muffler 3 8 NPT Exhaust Port For Optional Muffler Styles or Piping Exhaust Air In Submerged Applications Discharge Port 1 2 NPT Internal 1 NPT External 44mm Manifold Can Rotate 90 From Vertical...

Страница 7: ...n and strain to the pumping system A surge suppressor is recommended to further reduce pulsation in flow Air Supply Air supply pressure cannot exceed 125 psi 8 6 bar Connect the pump air inlet to an a...

Страница 8: ...CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure INStaLLatION gUIDe Top Discharge ball Valve Unit To order call...

Страница 9: ...rge suppressor What to Check Blocked air exhaust muffler Corrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Chec...

Страница 10: ...scharge piping and all other openings and connections Be certain the air supply is locked out or made non operational so that it cannot be started while work is being done on the pump Be certain that...

Страница 11: ...Models 85622 85628 85626 85637 Non Metallic REV1007 Page 9 This page left intentionally blank To order call 1 800 548 1191 or visit www partdeal com info partdeal com...

Страница 12: ...3 WET END KIT Santoprene Diaphragms Nitrile Spacer Gaskets Santoprene Check Balls PTFE Seats and PTFE Seals 271872 WET END KIT Santoprene Diaphragms PTFE Overlay Diaphragm PTFE Check Balls PTFE Seats...

Страница 13: ...ong 4 271992 271992 271992 14 Outer Chamber 2 271985 271985 271985 15 Diaphragm 2 252907 252907 271865 16 Overlay Diaphragm 2 252908 17 Suction Elbow 2 252909 252909 252909 18 Discharge Elbow 2 271994...

Страница 14: ...Drawing Dual Port Suction Model 85637 12 22 1 12 12 32 29 26 7 30 31 6 28 15 27 14 2 34 25 9 5 17 25 11 34 2 18 10 9 33 10 33 10 25 25 21 3 20 8 12 10 25 25 4 23 13 ILLUSTRATION SHOWS DIRECTION OF DI...

Страница 15: ...20 x 1 25 long 8 271991 13 Hex Flange Capscrew 5 16 18 x 88 long 8 271992 14 Outer Chamber 2 271985 15 Diaphragm 2 271865 17 Suction Elbow NPT 2 275810 18 Discharge Elbow 2 271994 20 Air Inlet Gasket...

Страница 16: ...arts list Item Part Number Description Qty 1 272836 Air Valve Assembly 1 1 A 273051 Body Air Valve 1 1 B 252929 Sleeve and Spool Set 1 1 C 252927 O Ring 8 1 E 273046 End Cap 2 1 F 273047 O Ring 2 1 G...

Страница 17: ...ed clerance Sleeves and spools cannot be interchanged STEP 3 Reassembly of the air distribution valve Install one end cap with o rings items 1 E 1 C and 1 F into one end of the air valve body item 1 A...

Страница 18: ...ricate outside diameter of the sleeve and o rings Then carefully insert sleeve into valve body Take CAUTION when inserting sleeve not to shear any o rings Install retaining ring to sleeve Generously l...

Страница 19: ...ach end of the intermediate cavity Inspect for wear or damage Replace plunger as needed Apply a light coating of grease to each o ring and re install the plungers in to the bushings Push the plungers...

Страница 20: ...9 15 27 14 13 31 6 28 15 16 27 14 11 25 11 13 15 16 27 14 13 31 6 15 14 11 25 11 13 15 13 286 116 000 only 14 Use With TPE Diaphragms Only 31 6 28 19 15 27 14 11 25 11 13 19 15 27 14 13 31 6 28 15 16...

Страница 21: ...ters 120 in lbs Santoprene 13 56 Newton meters Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate for stress relaxation in the clamped assembly Step 5 Ins...

Страница 22: ...pherical surface The check valve seats items 34 should be inspected for cuts abrasive wear or embedded material on the surfaces of both the external and internal chamfers The spherical surface of the...

Страница 23: ...the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right Converting the pump for piping the exhaust air The following steps are necessary to convert the pump...

Страница 24: ...ive 98 37 EC Safety of Machinery This product has used EN 809 Pumps and Pump Units for Liquids Common Safety Requirements harmonized standards to verify conformance Signature of authorized person Date...

Отзывы: