background image

Page Number - 9

Form 403846

TROUBLESHOOTING

Problem

Possible Cause

Solution

Pump does not operate.

Restricted or inadequate air supply.

Check air supply pressure and air hose
diameter (see Airmotor manual for
minimum air supply hose diameter)

Obstructed material output,

Check output line for restrictions.

Erratic or accelerated operation.

Pump is not primed.

Prime pump (see "Pump Priming"
Instructions).

Insufficient material supply

Refill material supply.

Material is too heavy for priming.

Lower output with material valve. Increase

pressure to pressure primer (if in use).
Check for inlet restrictions.

Pump operates on "down" stroke only

Worn or damaged Piston O-rings (Item 21)

Check and replace if needed.

(missing "up" stroke)

or Piston Check (Items 22 & 23).

Pump operates on "up" stroke only

Worn or damaged Inlet Check (Items 32

Check and replace

 

if needed.

(missing "down" stroke).

& 33).
Insufficient material supply. Pump is not

Check inlet for restrictions Lower output

intaking enough material to dispense on

with material valve.

both strokes.

Pump is operating but not dispensing

Inlet Check (Items 32 & 33) is not seating

Check and replace if needed.

material.

or is damaged

Models 84918 and 84919

POWER-MASTER III TRANSFER PUMPS 

Shovel Type Foot Valve

Declaration by the manufacturer as defined by Machinery Directive 89/392EEC Annex IIB

Herewith we declare that the supplied model of PowerMaster Pumps 84918 and 84919.

Is intended to be incorpoated into machinery covered by this directive and must not be put into service until the machiner into 

shich it is to be incorpoated has been declared in conformity with the provisions of the directive 91/386/EEC.

Applied harmonized standards in particular:

EN 292   

Safety of machinery - Basic concepts, general principles for design - Part 2: Technical principles and 

 

 

specifications

EN 809   

Pumps and pump units for liquids - Common safety requirements

EN 983   

Safety of machinery - Safety requirements for fluid power systems and their components - Pneumatics

EN 1050  

Safety of machinery - Principles for risk assessment

Paul Conley, Cheif Engineer 

8/24/09

To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]

Содержание 84918

Страница 1: ...Page Section A50 91 Form 403846 AUG 2009 Models 84918 and 84919 POWER MASTER III TRANSFER PUMPS Shovel Type Foot Valve To order call 1 800 548 1191 or visit www partdeal com info partdeal com...

Страница 2: ...ble gas DO NOT attempt to repair or disassemble the equipment while the system is pressurized TIGHTEN all fluid connections securely before using this equipment ALWAYS read and follow the fluid manufa...

Страница 3: ...PRESSURE psi bar DIMENSION A in cm DIMENSION B in cm 84918 2030 84806 24 1 2400 168 100 7 17 1 4 44 45 3 8 115 2028 84804 12 1 2400 168 200 14 84803 6 1 1200 84 200 14 84919 2031 84806 24 1 2400 168...

Страница 4: ...aterial The Power Master III pump is a double act ing pumps material on up down stroke positive displace ment reciprocating pump and as such intakes material only on the up stroke To prime pump open o...

Страница 5: ...tem 8 15 Remove Gland Nut Item 3 from Outlet Body Item 8 16 Remove Pipe Plug Item 9 from Outlet Body Item 8 17 Remove Outlet Body Item 14 from Outlet Body Item 8 18 Remove Ball Item 12 Check Seat Item...

Страница 6: ...Lbs 4 5 6 7 17 8 9 10 11 10 12 13 14 20 21 22 21 23 Torque to 55 60 Ft Lbs 15 25 26 27 28 29 30 31 32 33 34 35 Torque to 200 220 Ft Lbs Models 84918 and 84919 POWER MASTER III TRANSFER PUMPS Shovel T...

Страница 7: ...6 7 8 9 20 21 22 21 15 13 12 10 11 10 23 Torque to 55 60 Ft Lbs 24 16 17 19 18 19 25 26 27 28 30 31 32 33 34 35 Torque to 200 220 Ft Lbs 14 29 Models 84918 and 84919 POWER MASTER III TRANSFER PUMPS S...

Страница 8: ...1 270038 270038 24 O ring nitrile 1 N A 34309 25 Bushing Tube 1 270039 270034 26 Check Stop Insert 1 270037 270037 27 Retaining Ring 1 68482 68482 28 Guide Washer 1 45826 45826 29 Bushing and Plunger...

Страница 9: ...al to dispense on with material valve both strokes Pump is operating but not dispensing Inlet Check Items 32 33 is not seating Check and replace if needed material or is damaged Models 84918 and 84919...

Страница 10: ...r consequential damages therefore the above limitation or exclusion may not apply to you This warranty gives you specific legal rights You may also have other rights that vary by jurisdiction Customer...

Отзывы: